SNAS605AR – MARCH 2013 – REVISED DECEMBER 2015
9.7.8.8 PLL2_LF_C4, PLL2_LF_C3
This register controls the integrated loop filter capacitors.
Table 72. Register 0x16D
POR
BIT
NAME
DESCRIPTION
DEFAULT
Internal loop filter components are available for PLL2, enabling either 3rd or 4th order loop
filters without requiring external components.
Internal loop filter capacitor C4 can be set according to the following table.
Field Value
Resistance
0 (0x00)
10 pF
1 (0x01)
15 pF
2 (0x02)
29 pF
3 (0x03)
34 pF
4 (0x04)
47 pF
5 (0x05)
52 pF
7:4
PLL2_LF_C4
0
6 (0x06)
66 pF
7 (0x07)
71 pF
8 (0x08)
103 pF
9 (0x09)
108 pF
10 (0x0A)
122 pF
11 (0x0B)
126 pF
12 (0x0C)
141 pF
13 (0x0D)
146 pF
14 (0x0E)
Reserved
15 (0x0F)
Reserved
Internal loop filter components are available for PLL2, enabling either 3rd or 4th order loop
filters without requiring external components.
Internal loop filter capacitor C3 can be set according to the following table.
Field Value
Resistance
0 (0x00)
10 pF
1 (0x01)
11 pF
2 (0x02)
15 pF
3 (0x03)
16 pF
4 (0x04)
19 pF
5 (0x05)
20 pF
3:0
PLL2_LF_C3
0
6 (0x06)
24 pF
7 (0x07)
25 pF
8 (0x08)
29 pF
9 (0x09)
30 pF
10 (0x0A)
33 pF
11 (0x0B)
34 pF
12 (0x0C)
38 pF
13 (0x0D)
39 pF
14 (0x0E)
Reserved
15 (0x0F)
Reserved
Copyright © 2013–2015, Texas Instruments Incorporated
89
Product Folder Links: