SNAS605AR – MARCH 2013 – REVISED DECEMBER 2015
8 Parameter Measurement Information
8.1 Charge Pump Current Specification Definitions
I1 = Charge Pump Sink Current at V
CPout
= V
CC
-
Δ
V
I2 = Charge Pump Sink Current at V
CPout
= V
CC
/2
I3 = Charge Pump Sink Current at V
CPout
=
Δ
V
I4 = Charge Pump Source Current at V
CPout
= V
CC
-
Δ
V
I5 = Charge Pump Source Current at V
CPout
= V
CC
/2
I6 = Charge Pump Source Current at V
CPout
=
Δ
V
Δ
V = Voltage offset from the positive and negative supply rails. Defined to be 0.5 V for this device.
8.1.1 Charge Pump Output Current Magnitude Variation Vs. Charge Pump Output Voltage
8.1.2 Charge Pump Sink Current Vs. Charge Pump Output Source Current Mismatch
8.1.3 Charge Pump Output Current Magnitude Variation Vs. Ambient Temperature
26
Copyright © 2013–2015, Texas Instruments Incorporated
Product Folder Links: