background image

1

Introduction

User's Guide

SLLU098A – June 2007 – Revised July 2009

Dual-Channel Digital Isolator EVM

Contents

1

Introduction

...................................................................................................................

1

1.1

Overview

.............................................................................................................

2

1.2

Functional Configuration of the Dual-Channel Digital Isolator

................................................

2

1.3

The EVM Signal Paths of the ISO7220x and ISO7221x Isolators

...........................................

3

1.4

The ISO7220x EVM Configuration

...............................................................................

5

1.5

The ISO7221x EVM Configuration

...............................................................................

6

2

EVM Setup and Operation

..................................................................................................

7

2.1

Overview

.............................................................................................................

7

List of Figures

1

The ISO7220x and ISO7221x Pinouts

....................................................................................

2

2

The ISO7220x Same-Channel Direction Schematic

....................................................................

3

3

The ISO7221x Opposing-Channel Direction Schematic

................................................................

4

4

ISO7220x EVM, Top View

.................................................................................................

5

5

ISO7220x EVM, Bottom View

.............................................................................................

5

6

The ISO7221x EVM Top View

.............................................................................................

6

7

The ISO7221x EVM Bottom View

.........................................................................................

6

8

Basic EVM Operation

.......................................................................................................

7

9

Typical Input and Output Waveforms

.....................................................................................

7

List of Tables

1

ISO7220x EVM Connections

...............................................................................................

3

2

ISO7221x EVM Connections

...............................................................................................

4

This user's guide details the evaluation module (EVM) operation of the factory installed ISO7220M
dual-channel digital isolator. However, the EVM board may be reconfigured by a user for use with any of
the ISO7220x or ISO7221x dual-channel isolators.

The EVM may be reconfigured for use with the ISO7220A, ISO7220B and ISO7220C same-channel
direction isolators and the ISO7221A, ISO7221A, ISO7221C and ISO7221M opposing-channel direction
isolators.

This guide also explains the user configurable I/O loads for both dual-channel isolator EVM configurations,
and presents a typical lab setup with input and output waveforms.

SLLU098A – June 2007 – Revised July 2009

Dual-Channel Digital Isolator EVM

1

Submit Documentation Feedback

Содержание ISO7220 Series

Страница 1: ...m View 6 8 Basic EVM Operation 7 9 Typical Input and Output Waveforms 7 List of Tables 1 ISO7220x EVM Connections 3 2 ISO7221x EVM Connections 4 This user s guide details the evaluation module EVM operation of the factory installed ISO7220M dual channel digital isolator However the EVM board may be reconfigured by a user for use with any of the ISO7220x or ISO7221x dual channel isolators The EVM m...

Страница 2: ...he proper dc level of the output If this dc refresh pulse is not received for more than 4 µs the input is assumed to be unpowered or not functional and the failsafe circuit drives the output to a logic high state CAUTION Note that although these devices provide galvanic isolation of up to 4000 V this EVM cannot be used for isolation voltage testing It is designed for the examination of device oper...

Страница 3: ...l isolators Figure 2 The ISO7220x Same Channel Direction Schematic Table 1 ISO7220x EVM Connections Connection Label Description J1 SMA connector to the INB input pin 3 J2 SMA connector to the OUTB output pin 6 J3 SMA connector to the INA input pin 2 J4 SMA connector to the OUTA output pin 7 P1 VCC1 Input power supply banana jack P2 VCC2 Output power supply banana jack P3 GND1 Input power ground c...

Страница 4: ...bel Description J1 SMA connector to the INB input pin 3 J2 SMA connector to the OUTB output pin 6 J3 SMA connector to the OUTA output pin 2 J4 SMA connector to the INA input pin 7 P1 VCC1 Input power supply banana jack P2 VCC2 Output power supply banana jack P3 GND1 Input power ground connection banana jack P4 GND2 Output power ground connection banana jack JMP1 3 pin jumper VCC1 input GND1 JMP2 3...

Страница 5: ...are 50 Ω resistors from each input to ground and are located on the bottom of the board as shown in Figure 5 Figure 4 ISO7220x EVM Top View The output channel configuration of the ISO7220x EVM has the OUTA pin 7 and OUTB pin 6 of Figure 1 and Figure 2 connected to SMA connector J2 and J4 through 0 Ω series resistor R4 and R6 Figure 5 ISO7220x EVM Bottom View The pads for R3 R7 C1 C12 C13 and C14 a...

Страница 6: ...e 6 The ISO7221x EVM Top View The output channel configuration of the ISO7221x EVM has the OUTA pin 2 and OUTB pin 6 of Figure 1 and Figure 3 connected to SMA connector J3 and J2 through 0 Ω series resistor R8 and R4 R1 and R7 are 50 Ω resistors from each input to ground on the bottom of the board shown in Figure 7 Figure 7 The ISO7221x EVM Bottom View The pads for R3 R5 C1 C12 C13 and C14 are ava...

Страница 7: ... If both sides are to be evaluated at the same supply voltage only one power supply is required and can be used to power both sides of the EVM CAUTION Note that this EVM is for operating parameter performance evaluation only and not designed for isolation voltage testing Any voltage applied above the 5 5 V maximum recommended operating voltage of the digital isolators will damage the EVM Figure 8 ...

Страница 8: ...t temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engineer or visit www ti com esh No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine process or combination in which such TI products or services might be or are used FCC Warning This evaluation...

Страница 9: ...ice TI is not responsible or liable for any such statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an agreement specifically governing such use Buyers represent that they have all necessary expertis...

Отзывы: