9.3.9.1 Flags and Fault Condition Response
below details the BQ25157 behavior when a fault condition occurs.
Table 9-5. Interrupt Triggers and Fault Condition Response
FAULT / FLAG
DESCRIPTION
INTERRUPT
TRIGGER
BASED ON
STATUS BIT
CHANGE
CHARGER
BEHAVIOR
CHARGER
SAFETY TIMER
LS/LDO
BEHAVIOR
PMID
BEHAVIOR
NOTES
CHRG_CV_FLA
G
Set when
charger enters
Constant Voltage
operation
Rising Edge
Enabled
No effect
N/A
IN powered if
V
IN
is valid
CHARGE_DONE
_FLAG
Set when
charger reaches
termination
Rising Edge
Paused-
Charging
resumes with
VIN or CE toggle
or when V
RCH
is
reached
Reset
N/A
IN powered if
V
IN
is valid
IINLIM_ACTIVE_
FLAG
Set when Input
Current Limit
loop is active
Rising Edge
Enabled.
Reduced charge
current.
Doubled if option
is enabled
N/A
IN powered VIN
powered unless
supplement
mode condition
is met.
VDPPM_ACTIVE
_FLAG
Set when DPPM
loop is active
Rising Edge
Enabled.
Reduced charge
current.
Doubled if option
is enabled
N/A
VIN powered
unless
supplement
mode condition
is met.
VINDPM_ACTIV
E_FLAG
Set when
VINDPM loop is
active
Rising Edge
Enabled.
Reduced charge
current.
Doubled if option
is enabled
N/A
VIN powered
unless
supplement
mode condition
is met.
THERMREG_AC
TIVE
Set when
Thermal Charge
Current Foldback
(Thermal
Regulation) loop
is active
Rising Edge
Enabled.
Reduced charge
current.
Doubled if option
is enabled
N/A
VIN powered
unless
supplement
mode condition
is met.
VIN_PGOOD_FL
AG
Set when VIN
changes PGOOD
status
Rising and
Falling Edge
If
VIN_PGOOD_S
TAT is low,
charging is
disabled.
Reset
N/A
VIN powered (if
VIN_PGOOD_S
TAT=1) unless
PMID_MODE is
not 00.
Interrupt will not
be sent if device
powers up with
VIN_PGOOD
condition and
V
BAT
<
V
BATUVLO
VIN_OVP_FAUL
T_FLAG
Set when V
IN
>
V
OVP
Rising Edge
Charging is
paused until
condition
disappears
Reset
N/A
BAT powered
BAT_OCP_FAUL
T_FLAG
Set when I
BAT
>
I
BATOCP
Rising Edge
Disabled (BAT
only condition)
N/A
N/A
Disconnect BAT
BAT_UVLO_FAU
LT_FLAG
Set when V
BAT
<
V
BATUVLO
Rising Edge
Enabled
No effect
N/A
IN powered of
V
IN
is valid
TS_COLD_FLAG
Set when V
TS
>
V
TS_COLD
Rising Edge
Charging paused
until condition is
cleared
Paused
N/A
IN powered of
V
IN
is valid
TS_COOL_FLA
G
Set when
V
TS_COLD
> V
TS
>
V
TS_COOL
Rising Edge
Enabled.
Reduced charge
current.
Doubled if option
is enabled
N/A
IN powered of
V
IN
is valid
SLUSEC5 – DECEMBER 2020
28
Copyright © 2020 Texas Instruments Incorporated
Product Folder Links:
Содержание BQ25157
Страница 107: ...D Max E Max 2 045 mm Min 1 645 mm Min 1 985 mm 1 585 mm...
Страница 108: ......
Страница 109: ......