8.5 Electrical Characteristics (continued)
V
IN
= 5V, V
BAT
= 3.6V. -40°C < T
J
< 125°C unless otherwise noted. Typical data at T
J
= 25°C
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
/MR INPUT
R
PU
Internal pull up resistance
90
125
170
kΩ
V
IL
/MR Input Low threshold level
V
BAT
> V
BUVLO
0.3
V
/INT, /PG OUTPUTS
V
OL
Output Low threshold level
V
PULLUP
= V
IO
= 1.8V, I
LOAD
= 5mA
0.25 *
V
IO
V
I
LKG
/INT Hi level leakage Current
High Impedance, V
PULLUP
= V
IO
= 1.8V
1
µA
/CE, /LP INPUTS
R
PDOWN
/CE pull down resistance
900
kΩ
V
IL
Input Low threshold level
V
IO
= 1.8V
0.45
V
V
IH
/CE Input High Threshold level
V
IO
= 1.8V
1.35
V
8.6 Timing Requirements
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
BATTERY CHARGE TIMERS
t
MAXCHG
Charge safety timer
Programmable range
180
720
min
t
PRECHG
Precharge safety timer
0.25 * t
MAXCHG
WATCHDOG TIMERS
t
WATCHDO
G_SW
SW Watchdog timer
25
50
s
t
HW_RESE
T_WD
HW reset watchdog timer
WATCHDOG_15S_ENABLE = 1
15
s
LDO
t
ON_LDO
Turn ON time
100mA load, to 90% V
LDO
500
µs
t
OFF_LDO
Turn OFF time
100mA load, to 10% V
LDO
30
µs
t
PMID_LDO
_DELAY
Delay between PMID and LDO enable
during power up
Startup
20
ms
PUSHBUTTON TIMERS (/MR)
t
WAKE1
WAKE1 Timer. Time from /MR falling
edge to INT being asserted.
MR_WAKE1_TIMER = 0
106
125
144
ms
MR_WAKE1_TIMER = 1
425
500
575
ms
t
WAKE2
WAKE2 Timer. Time from /MR falling
edge to INT being asserted.
MR_WAKE2_TIMER = 0
0.85
1
1.15
s
MR_WAKE2_TIMER = 1
1.7
2
2.3
s
t
RESET_W
ARN
RESET_WARN Timer. Time prior to HW
RESET
MR_RESET_WARN = 00
0.42
0.5
0.58
s
MR_RESET_WARN = 01
0.85
1
1.15
s
MR_RESET_WARN = 10
1.27
1.5
1.73
s
MR_RESET_WARN = 11
1.7
2
2.3
s
t
HW_RESE
T
HW RESET Timer. Time from /MR falling
edge to HW Reset
MR_HW_RESET = 00
3.4
4
4.6
s
MR_HW_RESET = 01
6.8
8
9.2
s
MR_HW_RESET = 10
8.5
10
11.5
s
MR_HW_RESET = 11
11.9
14
16.1
s
t
RESTART(
AUTOWAKE
)
RESTART Timer. Time from /MR HW
Reset to PMID power up
AUTOWAKE = 00
0.52
0.6
0.68
s
AUTOWAKE = 01
1.05
1.2
1.35
s
AUTOWAKE = 10
2.11
2.4
2.69
s
AUTOWAKE = 11
4.4
5
5.6
s