2.5.3 Right Panels – Signal Source
Figure 7a: WaveVision 5 main window command buttons
Open the
Signal Source
panel on the right side of the window and confirm that the ADC0XD1520RB is available
and confirm that it is selected. There are five possible modes of operation selectable here:
•
NonDES I ch –
Dual channel mode capturing and viewing the I-channel data
•
NonDES Q ch –
Dual channel mode capturing and viewing the Q-channel data
•
NonDES I and Q –
Dual channel mode capturing and viewing both the I- and Q-channel data
•
DESI Mode –
Double Edge Sample (interleaved) mode with I input
•
DESQ Mode –
Double Edge Sample (interleaved) mode with Q input
Double Edge Sampling (DES)
– Double edge sampling works much in the same way as single edge
sampling except that the signals is sampled both on the rising and falling edge of the sample clock. This
effectively doubles the sample rate. In this mode, both converters inside the ADC0XD1520 work on a
common input signal. The various DES modes are selected from the
Signal Source
tab on the right side
and have requirements for how the inputs must be driven. See the datasheet for more details.