7
1
Heat pump unit.
25
50 mm polyurethane insulation.
2
Control panel.
26
High pressure switch – automatic reset.
3
External PVC jacket.
27
Safety thermostat, manual reset.
4
Enameled storage tank
28
Controller box.
5
Upper storage tank probe. “T3”
29
Probe for solar coil thermosensor.
6
Lower storage tank probe. “T2”
30
Low pressure switch – automatic reset.
7
Refrigerant recharge needles.
31
4-way defrosting valve
8
Ambient air recirculation fan.
32
Upper decorative panel
9
Electronically regulated expansion valve.
33
Back decorative panel
10
High-efficiency finned evaporator.
34
Front decorative panel
11
Air outlet (ø 160 mm).
35
Lower decorative panel (condense trap)
12
Air inlet (ø 160 mm).
36
Condenser.
13
Hermetically-sealed rotary compressor.
37
Protective fan grid
14
Compressor’s accumulator
38
Return gas temperature “T5”
15
(1.5 kW – 230 W) El. heater
39
Coil temperature “T4”
16
Condenser outlet line - liquid
40
Bolts M6x60
17
Condenser inlet line – hot gas
41
Ambient temperature “T1”
18
Replaceable magnesium anode.
22
Condensates drain (G 3/4”).
Descriptions
HP3.1 260S
HP3.1 260
HP 3.1 200S
HP3.1 200
Performance data acc. EN16147:2017
Load profile
XL
XL
L
L
Hot water temperature set point
°C
55
55
55
55
Heating up time; th
h:m
· (EN 16147:2017 – A20/W55)
7:23
7:23
5:41
5:41
· (EN 16147:2017 - A14/W55)
8:49
8:49
6:33
6:33
· (EN 16147:2017 - A7/W55)
10:12
10:12
7:45
7:45
· (EN 16147:2017 – A2/W55)
13:15
13:15
8:59
8:59
Heating up time in BOOST mode (A7/W10-55)
h:m
4:21
4:21
3:47
3:47
Average heat pump power consumption at initial
heat up Weh-HP / th
kW
WARNING! Packaging items (staples, cardboard boxed, etc.) must not be left within the reach of children
as they are dangerous.
(*) Note: at the manufacturer’s discretion, the type of packaging may be subject to change.
For the entire period in which the equipment remains idle, waiting to be used, it is opportune to protect it from atmospheric agents.
Positions
permitted
for transporting and handling
Allowed! (Fig.2f)
WARNING! During the product handling and installation stages, it is forbidden to put the upper part of
the device under any kind of stress whatsoever due to the fact that it is not of a structural nature.
Positions that are
not permitted
for transporting and handling purposes:
Not Allowed! (Fig.2g)
While handling, do not catch the unit onto upper plastic panels! There is a risk to damage them!