Installation and Setup
|
7-9
Engineered to Endure
J1, J2 and J3
The A: side Tx Output (J1), Tx Input (J2), and B: side Tx Output (J3) connectors are
Type-N connectors.
M&C Interface J4 and J6
The M&C interface connectors are 19-pin circular connectors used to enable the
IBUCs to exchange communications and status, as well as monitor and control the
waveguide switch. Pin assignments are shown in
. The M&C cables used to
connect to the Tx 1+1 interface module to the IBUCs are supplies with the Tx 1+1
system.
Table 7.2
Pin Assignments for M&C Interface connectors J1, J2, and J3
Reference Designator
Function
J1
TX A: OUTPUT, L-BAND, 10 MHz, FSK
J2
TX INPUT, L-BAND, 10 MHz, FSK
J3
TX B: OUTPUT, L-BAND, 10 MHz, FSK
Table 7.3
Pin Assignments for M&C Interface Connectors J4 and J6
Pin
Function
A
RS485(+)
B
RS485(-)
C
HAND-HELD TERMINAL POWER(+)
D
RS232 RXD
E
RS232 TXD
F
HAND-HELD TERMINAL POWER(-)
G
ALARM OUTPUT
H
NOT USED
J
NOT USED
K
NOT USED
L
IBUC ALARM OUTPUT Normally Open
M
IBUC ALARM OUTPUT Common
N
IBUC ALARM INPUT/MUTE
P
IBUC ALARM OUTPUT Normally Closed
R
1+1 SWITCH COMMAND A:
S
1+1 SWITCH COMMAND B:
T
1+1 SWITCH INDICATOR A:
U
1+1 SWITCH INDICATOR B:
V
1+1 REDUNDANCY ENABLE
Содержание IBUC 3
Страница 8: ...vi Engineered to Endure ...
Страница 12: ...viii Engineered to Endure ...
Страница 13: ...ix REVISION HISTORY Engineered to Endure Revision Date Description A 1 26 2021 Initial Public Release ...
Страница 14: ...x Engineered to Endure ...
Страница 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Страница 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Страница 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Страница 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Страница 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Страница 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Страница 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Страница 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Страница 168: ...E 6 IBUC 3 IBUC 3G Operations Manual Legacy Binary Command Message Structure Engineered to Endure ...
Страница 223: ...Reference Drawings G 3 Engineered to Endure Figure G 2 Fabrication Drawing FBD 21984 XXXX Rev B page 1 of 2 ...
Страница 225: ...Reference Drawings G 5 Engineered to Endure Figure G 4 Example Installation Drawing IND 10521 0011 Rev A ...
Страница 227: ...Data Sheets G 7 Engineered to Endure ...
Страница 228: ...G 8 IBUC 3 IBUC 3G Operations Manual Component Specifications and Reference Drawings Engineered to Endure ...
Страница 235: ...I n d e x 3 Engineered to Endure ...
Страница 236: ...I n d e x 4 ...