7-20
|
IBUC
3
,
IBUC
3
G
Operations Manual: Transmit Redundant Systems
Engineered to Endure
If cloning is disabled set the following commands to configure the RS485 interface:
A: Side IBUC
C4A=1 // RS485 Address
C4D=20 // RS485 Delay
C4R=9600 // RS485 Baud rate
If ASCII mode is desired type
C4M=0 // RS485 Mode (Not factory default)
If Legacy mode is desired type
C4M=1 // RS485 Mode
B: Side IBUC
C4A=2 // RS485 Address
C4D=20 // RS485 Delay
C4R=9600 // RS485 Baud rate
If ASCII mode is desired type
C4M=0 // RS485 Mode (Not factory default)
If Legacy mode is desired type
C4M=1 // RS485 Mode
If cloning is enabled, C4D, C4R and C4M commands will be automatically cloned
from Master to the Slave unit. Thus, when cloning is enabled use the following steps:
1. Configure Master IBUC as shown above
2. Set the C4A command directly at the slave unit.
RS485
Communicating with the IBUC across RS485 can be through ASCII or a proprietary
binary protocol known as Legacy Binary.
ASCII Mode
The default configuration is Legacy Binary mode so you will need to reconfigure the
IBUC in order to use ASCII mode. ASCII mode can be selected by using any of the
M&C interfaces.
Communication through a terminal emulation program such as HyperTerminal
requires an on-board RS485 card in the host computer. In HyperTerminal, type the
password command:
<0001/CPE=1234
for the A: side IBUC and
<0002/CPE=1234
for the B:
side IBUC, and then press
Enter
. When the < prompt reappears, the IBUC is ready to
accept commands. In the previous example,
<0001/
is the address of the IBUC followed
by the desired command. Nothing is returned for the CPE command. If there is no
error then it was successful.
Содержание IBUC 3
Страница 8: ...vi Engineered to Endure ...
Страница 12: ...viii Engineered to Endure ...
Страница 13: ...ix REVISION HISTORY Engineered to Endure Revision Date Description A 1 26 2021 Initial Public Release ...
Страница 14: ...x Engineered to Endure ...
Страница 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Страница 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Страница 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Страница 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Страница 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Страница 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Страница 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Страница 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Страница 168: ...E 6 IBUC 3 IBUC 3G Operations Manual Legacy Binary Command Message Structure Engineered to Endure ...
Страница 223: ...Reference Drawings G 3 Engineered to Endure Figure G 2 Fabrication Drawing FBD 21984 XXXX Rev B page 1 of 2 ...
Страница 225: ...Reference Drawings G 5 Engineered to Endure Figure G 4 Example Installation Drawing IND 10521 0011 Rev A ...
Страница 227: ...Data Sheets G 7 Engineered to Endure ...
Страница 228: ...G 8 IBUC 3 IBUC 3G Operations Manual Component Specifications and Reference Drawings Engineered to Endure ...
Страница 235: ...I n d e x 3 Engineered to Endure ...
Страница 236: ...I n d e x 4 ...