![Terrasat IBUC 3 Скачать руководство пользователя страница 117](http://html.mh-extra.com/html/terrasat/ibuc-3/ibuc-3_operation-manual_1089882117.webp)
Service and Maintenance
|
7-27
Engineered to Endure
the DC cable that is connected to the IBUC J3 (DC Input) connector. If it is not,
check the PSUI outputs and cables.
4. If the L-band, 10 MHz, and DC voltage (for DC-powered IBUCs) signals are
good, proceed to the
Tx Redundancy Output Verification
5. Disconnect the spectrum analyzer from the coaxial cable.
Tx Redundancy Output Verification
This check assumes that the L-band, 10 MHz, and DC inputs (for DC-powered
IBUCs) are at the correct levels.
1. Tx Output level is monitored and displayed in any of the IBUC M&C interfaces.
Alternately, you may connect a waveguide-to-coaxial adapter and a 40 dB high-
power attenuator to the Tx waveguide output.
2. Measure the Tx RF output with the spectrum analyzer connected at the waveguide
output. Ensure that the cable loss of the cable being used for the measurement has
been taken into account.
3. The RF power should be between rated power and rated power –25 dB. If it is not,
the IBUC is defective and should be returned to the factory for repair. The Terrasat
Repair Policy on
has information about returning a defective unit to the
factory.
4. If the IBUC Tx RF output measures good, check the waveguide, feedhorn and
antenna for proper operation.
Common Problems
The following common problems or occurrences have been noted during normal
troubleshooting:
• Supply voltage at IBUC is low or missing
• 10 MHz reference at the IBUC is at the wrong level or missing
• 10 MHz phase noise does not meet the minimum requirements
• Antenna is misaligned
• Bad OMT and/or antenna
• Damaged cables
• Antenna on the wrong satellite
• Tx L-band input level is misadjusted or turned off
• Water in the IBUC due to no gasket in the waveguide or a hole in the feed window.
• Water in the coaxial connectors
• Incorrect frequency settings
Содержание IBUC 3
Страница 8: ...vi Engineered to Endure ...
Страница 12: ...viii Engineered to Endure ...
Страница 13: ...ix REVISION HISTORY Engineered to Endure Revision Date Description A 1 26 2021 Initial Public Release ...
Страница 14: ...x Engineered to Endure ...
Страница 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Страница 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Страница 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Страница 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Страница 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Страница 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Страница 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Страница 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Страница 168: ...E 6 IBUC 3 IBUC 3G Operations Manual Legacy Binary Command Message Structure Engineered to Endure ...
Страница 223: ...Reference Drawings G 3 Engineered to Endure Figure G 2 Fabrication Drawing FBD 21984 XXXX Rev B page 1 of 2 ...
Страница 225: ...Reference Drawings G 5 Engineered to Endure Figure G 4 Example Installation Drawing IND 10521 0011 Rev A ...
Страница 227: ...Data Sheets G 7 Engineered to Endure ...
Страница 228: ...G 8 IBUC 3 IBUC 3G Operations Manual Component Specifications and Reference Drawings Engineered to Endure ...
Страница 235: ...I n d e x 3 Engineered to Endure ...
Страница 236: ...I n d e x 4 ...