background image

Section II.  Specifications 
System Ratings and Operating Parameters 

System Rating 

U.S. 

Production 

0.5  G.P.M.— 0.75 G.P.M.    

Capacity 

1100 Gallons  AMB-9S 

1000 Gallons  FD-MultiMedia 

2000 Gallons  Teros-UF Membrane 

Recommended Operating Limits for Feed Water 

 

Water Pressure 

20—125 psi 

Total Dissolved Solids 

Less than 500 ppm or 500 mg/l 

Temperature 35— 

110 

°

 F 

2— 43 

°

 C 

pH 

6.5 to 8.5 recommended 

Iron 

Less than 0.5 ppm   0r 0.5 mg/l 

Manganese 

Less than 0.05 ppm  Or 0.05 mg/l 

Hydrogen Sulfide 

Less than 0.3 ppm  Or 0.3 mg/l 

Chlorine 

0— 10 ppm  

Section III.  Preparation 
 

A. System Components 
 

The following components comprise the  Teros Systems.

 



Housing Top Assembly 



2 Housing sumps with O-rings 



Lead-Free drinking water faucet 



EZ-Adapter valve 



Plastic tubing and connectors 



AMB-9S AquaMetix block candle 



Teros UF Membrane 



*FD-MultiMedia— Only on 3S model. 

 

B.  Tools Recommended for Installation 

The following tools will cover most of the installation 

sites encountered. 

1.  3/8” variable speed drill 

2.  Extension work light  

3. Safety 

glasses 

4.  7/16” carbide drill bit 

5.  1/8” metal drill bit for pilot hole. 

6.  Center punch and hammer 

7.  Phillips head and flat blade screwdrivers 

8. Tubing 

cutter 

9.  Paper towels, broom and assorted clean up     ma-

terials 

 

C. Site Selection 

The Teros system was designed to fit under a sink, 

however, because of space limitations or other reasons, 
the system’s flexible design allows for other locations.  

When determining the location remember that access to 

a cold water tap line and ease of filter replacement are 

important considerations. 

 

All components and tubing should be located in an area 
which is not exposed to freezing temperatures.  If    

winter temperatures are sever, the area should be  

Содержание 2S

Страница 1: ...2S and 3S Under Counter UltraFiltration Drinking Water System Installation and Service Manual ...

Страница 2: ...This guidance pertains to people with HIV AIDS patients receiv ing treatment for cancer recipients of organ or bone marrow transplants transplant pa tients taking immunosuppressive drugs and persons who have congenital immuno deficiencies The EPA has stated that they do not know the importance of drinking water compared to other possible sources of Cryptosporidium to determine how most people beco...

Страница 3: ...to reduce unwanted contaminants in your water supply The following steps combine to give you the best in clear sparkling pure drink ing water Your system will include 2 or 3 filters depending on the model you chose This manual will cover both systems Water Inlet Water Outlet Water Inlet Water Outlet Teros 2S Teros 3S ...

Страница 4: ... connectors AMB 9S AquaMetix block candle Teros UF Membrane FD MultiMedia Only on 3S model B Tools Recommended for Installation The following tools will cover most of the installation sites encountered 1 3 8 variable speed drill 2 Extension work light 3 Safety glasses 4 7 16 carbide drill bit 5 1 8 metal drill bit for pilot hole 6 Center punch and hammer 7 Phillips head and flat blade screwdrivers...

Страница 5: ...ed for porcelain A carbide tipped masonry bit is a second choice Place a piece of tape over the area to be drilled to help prevent chipping Drill a pilot hole for the porcelain cutter When drilling the 7 16 hole drill slowly and care fully the porcelain chips easily After drilling clean the area well Iron filings if left in place can cause rust stains 2c Drilling a counter top NOTE treat ceramic t...

Страница 6: ... between wall studs on parti cleboard or drywall Do not drill through exterior cabinet walls or leave sharp wood screw points exposed in readily accessible cabinet interiors The close proximity of a dishwasher or a trash com pactor may require special fabrication of a mounting plate 1 The mounting bracket will accept either 10 or 12 mounting screws spaced on 6 centers Allow at least 4 of clearance...

Страница 7: ...nutes Then turn the tap on and allow water to run for 5 minutes This step is very important as the preservative inside the membrane must be flushed prior to FIRST use Once this is complete turn off the tap turn off the cold water valve and then turn the tap back on This will release excess air pressure from the membrane Final Assembly Now that the membrane has been flushed you can now remove the e...

Страница 8: ... com pletely closed Call dealer Leaks from faucet connector under neath the counter Check that tubing is properly inserted Check that tubing is cut straight Check that fitting is tight Low Production Filter s clogged Change filters Drawing No Part No Description 1 W9410103 FD MultiMedia 2 W9332415 Teros 3S Pre Filter 3 Teros 2S Teros 3S Upper Housing Assembly 4 AMB 9S Aquametix Block Filter 5 CFHF...

Страница 9: ...hall not apply to any part of the Teros System that is damaged because of occurrences including but not limited to neglect misuse alteration accident misapplication physical damage or damage caused by fire act of God freezing or hot water All replacement filters must be AquaCera brand replacement filters or the warranty is void If the unit is altered by anyone other than CFCI the warranty is void ...