Run the blue tubing along its course to the          

 

dispensing  faucet.  Trim to length.  To the end of 

 

the 7/16” stud on the faucet screw on the white 

 

faucet quick connect fitting.  Once snug by hand 

 

take a   pair of pliers and tighten the fitting an  

 

additional half turn.   

 

 

DO NOT OVER-TIGHTEN. 

NOTE:  if you want to pull the tubing out for some reason, 
push the ring around the tubing in and pull the tubing out. 

 

4.  Hang the Housing Assembly onto the mounting screws 

and tighten.   

 

 

DO NOT OVER-TIGHTEN. 

 
D. Start Up 

 

 

NOTE:  This is an excellent time to check for leaks 

from tubing not fully inserted into the push-fittings, or from 

threaded connectors that are not fully tightened. 

 
Membrane Flush 

 

Take the Teros membrane filter out of its protective pack-

aging.  Confirm that there is an o-ring situated on the 

threaded end.  Thread the membrane into the housing cap 

on the left side of the system (labeled inlet on Teros 2S 
system).  Thread filter into cap until hand tight.  Take the 

housing body/sump and confirm there is an o-ring situated 

in the groove at the top of the threaded end of the body/

sump.  Lubricate if necessary.  Thread the body/sump into 

the cap.  Hand-Tighten.   

Take the second housing body/sump and verify it has an   
o-ring seal and lubricate if necessary.   

DO NOT INSTALL AquaMetix AMB-9S FILTER AT THIS 

TIME.   

Thread body/sump into the cap.  Hand-Tighten. 

 
Slowly open the cold water valve to allow water to fill the 

system with water under pressure.  Flip the lever on the 

drinking water tap on.  There will be a slight delay before 

water begins to exit the tap.  Once water flows from the 

tap, turn tap off and allow system to sit unused for 5 

minutes.  Then, turn the tap on and allow water to run for 
5 minutes.  This step is very important as the preservative 

inside the membrane must be flushed prior to FIRST use. 

 

Once this is complete, turn off the tap; turn off the cold 

water valve and then turn the tap back on.  This will     

release excess air pressure from the membrane.   
 

 

 

Final Assembly 

 

Now that the membrane has been flushed, you can 
now remove the empty body/sump from the system so 

that the AquaMetix block can be installed.  Unscrew the 

body/sump from the housing– Note:  It will be full of 

water; watch for water spillage.  Remove the          

AquaMetix block filter from its packaging; verify the 

filter has an o-ring attached to the threaded end.  
Thread filter into the housing cap on the right side of 

the system (labeled outlet on both Teros 2S and 3S).  

Hand-Tighten this filter.  Next, take the housing body/

sump and thread back into the cap.  Hand-Tight. 

 

Final Flush of the system: 
 

Slowly open the cold water supply valve fully and allow 

water to flush for 5 minutes. 

 

Check For Leaks one last time. 

   
When the faucet is opened  expect air and grey colored 

water to be rinsed out .  This is perfectly normal and 

will last only seconds or not at all. 

 

Your system is now ready to use. 

Enjoy. 
 

Section V.  Operation and Maintenance 

 

 

A. Normal Operation 

 

You will notice a slight increase in flow 

for a few seconds after turning the water on 
each time; this is due to the back pressure on 

the membrane equalizing. Water will always 
be available on demand with flows of about 

1/2 a gallon per minute. 

 
B.  Changing Filters 

 

This system contains filters which must 

 

be replaced at regular intervals to 

 maintain 

proper 

performance.   

 
Replacement Frequency: 

 
Teros™ UF Membrane 

18-24 months  

Or when flow rate is drastically reduced. 
AMB-9S   12 

months 

FD-MultiMedia   12 

months 

(FD-MultiMedia only supplied with Teros 3S) 

Содержание 2S

Страница 1: ...2S and 3S Under Counter UltraFiltration Drinking Water System Installation and Service Manual ...

Страница 2: ...This guidance pertains to people with HIV AIDS patients receiv ing treatment for cancer recipients of organ or bone marrow transplants transplant pa tients taking immunosuppressive drugs and persons who have congenital immuno deficiencies The EPA has stated that they do not know the importance of drinking water compared to other possible sources of Cryptosporidium to determine how most people beco...

Страница 3: ...to reduce unwanted contaminants in your water supply The following steps combine to give you the best in clear sparkling pure drink ing water Your system will include 2 or 3 filters depending on the model you chose This manual will cover both systems Water Inlet Water Outlet Water Inlet Water Outlet Teros 2S Teros 3S ...

Страница 4: ... connectors AMB 9S AquaMetix block candle Teros UF Membrane FD MultiMedia Only on 3S model B Tools Recommended for Installation The following tools will cover most of the installation sites encountered 1 3 8 variable speed drill 2 Extension work light 3 Safety glasses 4 7 16 carbide drill bit 5 1 8 metal drill bit for pilot hole 6 Center punch and hammer 7 Phillips head and flat blade screwdrivers...

Страница 5: ...ed for porcelain A carbide tipped masonry bit is a second choice Place a piece of tape over the area to be drilled to help prevent chipping Drill a pilot hole for the porcelain cutter When drilling the 7 16 hole drill slowly and care fully the porcelain chips easily After drilling clean the area well Iron filings if left in place can cause rust stains 2c Drilling a counter top NOTE treat ceramic t...

Страница 6: ... between wall studs on parti cleboard or drywall Do not drill through exterior cabinet walls or leave sharp wood screw points exposed in readily accessible cabinet interiors The close proximity of a dishwasher or a trash com pactor may require special fabrication of a mounting plate 1 The mounting bracket will accept either 10 or 12 mounting screws spaced on 6 centers Allow at least 4 of clearance...

Страница 7: ...nutes Then turn the tap on and allow water to run for 5 minutes This step is very important as the preservative inside the membrane must be flushed prior to FIRST use Once this is complete turn off the tap turn off the cold water valve and then turn the tap back on This will release excess air pressure from the membrane Final Assembly Now that the membrane has been flushed you can now remove the e...

Страница 8: ... com pletely closed Call dealer Leaks from faucet connector under neath the counter Check that tubing is properly inserted Check that tubing is cut straight Check that fitting is tight Low Production Filter s clogged Change filters Drawing No Part No Description 1 W9410103 FD MultiMedia 2 W9332415 Teros 3S Pre Filter 3 Teros 2S Teros 3S Upper Housing Assembly 4 AMB 9S Aquametix Block Filter 5 CFHF...

Страница 9: ...hall not apply to any part of the Teros System that is damaged because of occurrences including but not limited to neglect misuse alteration accident misapplication physical damage or damage caused by fire act of God freezing or hot water All replacement filters must be AquaCera brand replacement filters or the warranty is void If the unit is altered by anyone other than CFCI the warranty is void ...

Отзывы: