ECOCONDENS SILVER PLUS
ISU-646:2016/GR-H str.25
6.2. Replacing a damaged control board in the control panel
If the control board need to be replaced follow the installation instructions attached to each board devoted as spare part.
Parameters of components for boilers ECOCONDENS SILVER PLUS 20,25,35
Item on the
scheme
Name
Parameters
Supply voltage from the
controller
5
Fan
NG40m
Power: 75 W (max)
230V AC
7
Pump Yonos Para PWM
Power: 45W
230V AC
8
Gas unit SIT SIGMA 848
Valve coil resistance: 3-4 EV1: 0,9 k
Ω
1-3 EV2: 6,4 k
Ω
230V AC
18
NTC sensor of CH water temperature 10K@25°C
β
=3977
SELV
19
Heating water pressure transducer
The output voltage: 0,5 V to 2,5 V (0 bar - 4 bar)
5V DC
26
Domestic water flow sensor
pin
SELV
27
NTC sensor of DHW water
temperature
10K@25°C
β
=3977
SELV
28
NTC sensor of CH water temperature
-return
10K@25°C
β
=3977
SELV
42
NTC sensor of outdoor temperature
10K@25°C
β
=3977
SELV
15
Temperature limiter 95°C
pin
SELV
16
Thermal fuse
pin
SELV
12
3-way valve
230V AC
System boiler