![TERMET ECOCONDENS SILVER PLUS-20 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/termet/ecocondens-silver-plus-20/ecocondens-silver-plus-20_instruction-manual_1089162019.webp)
ECOCONDENS SILVER PLUS
ISU-646:2016/GR-H str.17
Min power
Max power
ECOCONDENS SILVER PLUS
ECOCONDENS SILVER PLUS
20
25
35
20
25
35
Gas type
Inlet pressure
(mbar)
P04=12
P04=12
P04=12
P01= 25
P05=77
P01= 25 P05=76
P01= 25 P05=83
P03= 79
P02=99
P03= 79
P02= 99
P03=85
P02= 99
The content of CO2 in the flue gas [%]
The content of CO2 in the flue gas [%]
10.0
±0.2
9.5
±0.2
Gas flow rate [l/min.]**
Gas flow rate [l/min]**
2H-G20,
2E-G20
20 ÷ 25
4.8
+0.5
6.9
+0.5
7.3
+0.5
35.3
+1
44.3
+1
42.6
+1
53.1
+1
61.9
+1
71.4
+1
Min power
Max power
ECOCONDENS SILVER PLUS
ECOCONDENS SILVER PLUS
20
25
35
20
25
35
Gas type
Inlet pressure
(mbar)
P04=12
P04=12
P04=12
P01= 35 P05=66
P01= 35 P05=64
P01= 40 P05=63
P03= 77
P02= 99
P03= 79
P02= 99
P03= 86
P02= 99
The content of CO2 in the flue gas [%]
The content of CO2 in the flue gas [%]
11.0
+0.5
11.0
+0.5
Gas flow rate [l/min.]**
Gas flow rate [l/min]**
3B/P-G30
37
1.4
+0.5
2.0
+0.5
2.1
+0.5
10.2
+1
12.8
+1
12.3
+1
15.3
+1
17.9
+1
20.5
+1
Min power
Max power
ECOCONDENS SILVER PLUS
ECOCONDENS SILVER PLUS
20
25
35
20
25
35
Gas type
Inlet pressure
(mbar)
P04=12
P04=12
P04=12
P01= 40 P05=74
P01= 40 P05=72
P01= 40 P05=77
P03= 77
P02= 99
P03= 77
P02= 99
P03= 87
P02= 99
The content of CO2 in the flue gas [%]
The content of CO2 in the flue gas [%]
11.0
+0.5
11.0
+0.5
Gas flow rate [l/min.]**
Gas flow rate [l/min]**
3P-G31
37
1.8
+0.5
2.6
+0.5
2.8
+0.5
13.4
+1
16.9
+1
16.3
+1
20.3
+1
25.6
+1
27.0
+1
*During adjustment the boiler with removed cover of the chamber consider to increase amount of CO
2
given in table 0.2 ÷ 0.3%
**Listed in the table value of gas flow are indicative. Their value depends on the actual content of CO
2
in the flue gas.
***If the system boiler is connected to domestic water tank, set the parameter P02 in accordance with power of tank’s coil.
4.4. Fan characteristics
Fig.4.4.1. Characteristics of the fan- type NG40m
5. STARTUP AND OPERATION OF THE BOILER
5.1. Initial startup of the boiler
After installing the boiler, checking the accuracy and tightness of its connections and preparing for operation in accordance to this
instruction manual and applicable regulations first commissioning and user training for boiler operation and safety devices may be done
only by AUTHORISED SERVICE COMPANY.
5.2. Inclusion and operation
All boiler functions are performed by the boiler electronic control panel. Changing the operating mode and settings is done done by 4
buttons. Current state of the boiler is shown on the LCD display.
Fig. 5.2.1. Control panel
Содержание ECOCONDENS SILVER PLUS-20
Страница 31: ......