TM SERIES
1 - 4 0
4 7 2 7 9 7 - 1 / 1 5
T e r e x S o u t h D a k o t a , I n c .
T M S e r i e s
OPER
A
T
ION
GUIDEL
INES
OPERATION
BOOM OPERATION
The boom movement is limited to non-overcenter positions by a limit system. Do not depend on the limit
system to recognize when the booms are approaching a limit. Operate the unit knowing where the booms
and platform are in the work envelope to keep operation in the working area. See the Operational Limit
section for complete description.
TM105
TM125
The limit system will restrict operation of: Upper Boom up, Lower Boom down, Lower Boom Extension out.
The other functions are not limited. The Lower Boom Extension is limited to lower boom positions above 55
degrees (TM105) or 70 degrees (TM125). The Upper boom extension is not limited. If the Lower Boom is
extended below 55 degrees (TM105) or 70 degrees (TM125), the movements are limited. To operate fully
retract the Lower Boom Extension and the system will reset in a few seconds.
The platform will not be able to operate on the same side of the centerline of rotation as the elbow. If the
platform approaches the centerline the opposite boom function will operate. The platform will move up or
down depending on which function was operated to keep in a non-overcenter position.
OVERTURNING HAZARD
May result from operating outside the
All outriggers must be properly set before
Truck must be level before operation
proper platform & boom positions or
Platfrom must remain opposite lower boom
hinge pin from lower boom.
Lower boom can only extend when lower boom
is above 55 degree angle.
Upper boom can be extended at any time.
operation of the booms.
improper outrigger setup or truck position
of the booms.
DEATH OR SERIOUS INJURY
475373
55°
Extension
Allowed
Platform NOT
allowed on
this side of
center line
Platform allowed
on this side of
Center line of
Rotation
Extension not
allowed below 55°
OVERTURNING HAZARD
May result from operating outside the
All outriggers must be properly set before
Truck must be level before operation
proper platform & boom positions or
Platfrom must remain opposite lower boom
hinge pin from lower boom.
Lower boom can only extend when lower boom
is above 70 degree angle.
Upper boom can be extended at any time.
operation of the booms.
improper outrigger setup or truck position
of the booms.
DEATH OR SERIOUS INJURY
488127
70°
Extension
Allowed
Platform NOT
allowed on
this side of
center line
Platform allowed
on this side of
Center line of
Rotation
Extension not
allowed below 70°