Drive Control Fault Codes
122
Z
®
-60 DC • Z
®
-60 FE
Part No. 1307785GT
CAN
Object
Flash
Pattern
Description & Fault
Type
Cause
Effect
Solution
2632
10-8
Driver Assignment
Fault Type(s): 5
{X} = Driver number
that cause the fault
A Driver Output is used for
two or more functions
See Programmer »
Controller Setup »IO
Assignments » Coil Drivers:
Main Contactor Driver,
EM Brake Driver,
Hydraulic Contactor Driver
Fault Action:
None, unless a fault
action is programmed in
VCL
Set: Driver assignment
conflict (i.e., duplicate items
assigned to the same driver)
Clear: Resolve the
conflicted driver assignment,
then Reset Controller
2169
10-9
Coil Supply Fault
Fault Type(s):
1 = short to B- or HW
fault
2 = Coil Supply
disabled due to
shorted (internal)
driver.*
3 = Coil Supply
startup enable check
failed
4 = Coil Supply
startup disable check
failed
*a short must first be
detected
1. Short on driver loads
2. Dirty connector pins at
controller or device
3. Bad connector crimps or
faulty wiring
4. Controller is defective
ShutdownAll:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
ShutdownInterlock
ShutdownDriver1 to 7
ShutdownPD
FullBrake
ShutdownPump
ShutdownCoilSupply
ShutdownVehicle
ShutdownLower
ShutdownLift
Set: Short detected after the
startup check has passed
A low side driver short is
detected and the respective
fault action fails to cut-off
driver current
Coil supply startup test fails
Clear:
Reset Controller
2620
11-1
Analog 1 Out of
Range
Fault Type(s):
1 = above High limit
2 = below Low limit
1. Analog 1 input voltage is
above the parameter setting
of Analog 1 High
2. Analog 1 input voltage is
below the parameter setting
of Analog 1 Low
See Programmer »
Controller Setup » Analog
Inputs » Analog 1
See Programmer »
Controller Setup » Analog
Inputs » Configure » Analog
1 Low / Analog 1 High
Fault Action:
None, unless a fault
action is programmed in
VCL
Set:
(1) Input voltage (on pin) is
above the parameter’s set-
point threshold
(2) Input voltage (on pin) is
below the parameter’s set-
point threshold
Clear: Return the voltage to
within the allowed range,
then Reset Controller
2621
11-2 See Analog 1 Out of
Range
See Analog 1 Out of Range
See Analog 1 Out of
Range
See Analog 1 Out of Range
2622
11-3 See Analog 1 Out of
Range
See Analog 1 Out of Range
See Analog 1 Out of
Range
See Analog 1 Out of Range
2623
11-4 See Analog 1 Out of
Range
See Analog 1 Out of Range
See Analog 1 Out of
Range
See Analog 1 Out of Range
Содержание Genie Z-60 DC
Страница 55: ...August 2022 Service and Repair Manual Part No 1307785GT Z 60 DC Z 60 FE 43 This page intentionally left blank ...
Страница 57: ...August 2022 Service and Repair Manual Manifolds Part No 1307785GT Z 60 DC Z 60 FE 45 ...
Страница 59: ...August 2022 Service and Repair Manual Manifolds Part No 1307785GT Z 60 DC Z 60 FE 47 ...
Страница 153: ...August 2022 Service and Repair Manual 141 Wiring Diagram Options from Z60H 2548 to 2999 ...
Страница 156: ...Service and Repair Manual August 2022 144 Wiring Diagram Options from Z60H 2548 to 2999 ...
Страница 157: ...August 2022 Service and Repair Manual 145 Electrical Schematic Options 4WD from Z60H 2548 to 2999 ...
Страница 160: ...Service and Repair Manual August 2022 148 Power Cable Wiring Diagram from Z60H 2548 to 2999 ...
Страница 161: ...August 2022 Service and Repair Manual 149 Wiring Diagram FE Models from Z60H 3000 Z60M 1000 ...
Страница 164: ...Service and Repair Manual August 2022 152 Wiring Diagram DC Models from Z60H 3000 Z60M 1000 ...
Страница 165: ...August 2022 Service and Repair Manual 153 Electrical Schematic from Z60H 2548 to 2999 ...
Страница 168: ...Service and Repair Manual August 2022 156 Electrical Schematic from Z60H 2548 to 2999 ...
Страница 169: ...August 2022 Service and Repair Manual 157 Ground Control Box Wiring Diagram from Z60H 2548 to 2999 ...
Страница 172: ...Service and Repair Manual August 2022 160 Ground Control Box Wiring Diagram from Z60H 2548 to 2999 ...
Страница 173: ...August 2022 Service and Repair Manual 161 Platform Control Box Wiring Diagram from Z60H 2548 to 2999 ...
Страница 176: ...Service and Repair Manual August 2022 164 Platform Control Box Wiring Diagram from Z60H 2548 to 2999 ...
Страница 177: ...August 2022 Service and Repair Manual 165 Electrical Schematic PCON from Z60H 2548 to 2999 ...
Страница 180: ...Service and Repair Manual August 2022 168 CAN BUS Wiring Diagram from Z60H 2548 to 2999 ...
Страница 181: ...August 2022 Service and Repair Manual 169 Electrical Schematic DCON from Z60H 3000 Z60M 1000 ...
Страница 184: ...Service and Repair Manual August 2022 172 Electrical Schematic GCON from Z60H 3000 Z60M 1000 ...
Страница 185: ...August 2022 Service and Repair Manual 173 Electrical Schematic PCON from Z60H 3000 Z60M 1000 ...
Страница 188: ...Service and Repair Manual August 2022 176 Electrical Schematic TCON from Z60H 3000 Z60M 1000 ...
Страница 189: ...August 2022 Service and Repair Manual 177 Wiring Diagram CAN BUS from Z60H 3000 Z60M 1000 ...
Страница 191: ...August 2022 Service and Repair Manual 179 Hydraulic Schematic ...
Страница 193: ......