Service and Repair Manual
August 2022
Drive Control Fault Codes
116
Z
®
-60 DC • Z
®
-60 FE
Part No. 1307785GT
CAN
Object
Flash
Pattern
Description & Fault
Type
Cause
Effect
Solution
2813
4-9
Parameter Change
Fault Type(s):
Reports the CAN
Object ID of parameter
While the Interlock was ON,
a safety-based parameter
was changed
Parameters with this
property are marked with a
[PCF] (Parameter Change
Fault) in the Parameter
menu listings
ShutdownVehicle:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
FullBrake
ShutdownPump
Set: Adjustment of a
parameter setting that
requires cycling of KSI
Clear:
Reset Controller
2710
5-1
User 1 Fault
Global Drive Shutdown
A serious fault (Genie
severity = 4) has occurred
on one motor controller that
requires that the other
motor controllers shut down
also
Drive Inhibited
Set: Serious fault on 1 or
more drive controllers
Clear:
Re-power with problem
corrected
2711
5-2
User 2 Fault
Internal CAN
communication error
1. CAN wiring
2. Damaged Controller
Drive Inhibited
Set: Loss of communication
between left and right motor
control sections
Clear:
Repower with CAN wiring
problem corrected or
replace controller
2712
5-3
User 3 Fault
Invalid Motor Type
Selection
Incompatible motor selected See User 1 fault (above)
Set:
Invalid Motor Type Selection
Clear:
Select valid Motor Type
2713
5-4
User 4 Fault
Front to Back CAN bus
fault
1. CAN wiring
2. Damaged Controller
See User 1 fault (above)
Set: Loss of communication
between front and rear
motor controllers
Clear:
Repower with CAN wiring
problem corrected or
replace controller
2820
6-8
VCL Run Time Error
Runtime errors are defined
using the VCL Error Module
and VCL Error
See the System Information
file:
Curtis Software Suite™ »
VCL Studio » Help
Using driver control
commands in VCL can lead
to VCL runtime errors if the
VCL command and the
driver assignment do not
match
ShutdownAll:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
ShutdownInterlock
ShutdownDriver1 to 7
ShutdownPD
FullBrake
ShutdownPump
ShutdownCoilSupply
ShutdownVehicle
ShutdownLower
ShutdownLift
Set: VCL Run Time Error
detected
Clear: Edit the VCL
application software to fix
this error condition; flash the
new compiled software and
matching parameter
settings; Reset Controller
Содержание Genie Z-60 DC
Страница 55: ...August 2022 Service and Repair Manual Part No 1307785GT Z 60 DC Z 60 FE 43 This page intentionally left blank ...
Страница 57: ...August 2022 Service and Repair Manual Manifolds Part No 1307785GT Z 60 DC Z 60 FE 45 ...
Страница 59: ...August 2022 Service and Repair Manual Manifolds Part No 1307785GT Z 60 DC Z 60 FE 47 ...
Страница 153: ...August 2022 Service and Repair Manual 141 Wiring Diagram Options from Z60H 2548 to 2999 ...
Страница 156: ...Service and Repair Manual August 2022 144 Wiring Diagram Options from Z60H 2548 to 2999 ...
Страница 157: ...August 2022 Service and Repair Manual 145 Electrical Schematic Options 4WD from Z60H 2548 to 2999 ...
Страница 160: ...Service and Repair Manual August 2022 148 Power Cable Wiring Diagram from Z60H 2548 to 2999 ...
Страница 161: ...August 2022 Service and Repair Manual 149 Wiring Diagram FE Models from Z60H 3000 Z60M 1000 ...
Страница 164: ...Service and Repair Manual August 2022 152 Wiring Diagram DC Models from Z60H 3000 Z60M 1000 ...
Страница 165: ...August 2022 Service and Repair Manual 153 Electrical Schematic from Z60H 2548 to 2999 ...
Страница 168: ...Service and Repair Manual August 2022 156 Electrical Schematic from Z60H 2548 to 2999 ...
Страница 169: ...August 2022 Service and Repair Manual 157 Ground Control Box Wiring Diagram from Z60H 2548 to 2999 ...
Страница 172: ...Service and Repair Manual August 2022 160 Ground Control Box Wiring Diagram from Z60H 2548 to 2999 ...
Страница 173: ...August 2022 Service and Repair Manual 161 Platform Control Box Wiring Diagram from Z60H 2548 to 2999 ...
Страница 176: ...Service and Repair Manual August 2022 164 Platform Control Box Wiring Diagram from Z60H 2548 to 2999 ...
Страница 177: ...August 2022 Service and Repair Manual 165 Electrical Schematic PCON from Z60H 2548 to 2999 ...
Страница 180: ...Service and Repair Manual August 2022 168 CAN BUS Wiring Diagram from Z60H 2548 to 2999 ...
Страница 181: ...August 2022 Service and Repair Manual 169 Electrical Schematic DCON from Z60H 3000 Z60M 1000 ...
Страница 184: ...Service and Repair Manual August 2022 172 Electrical Schematic GCON from Z60H 3000 Z60M 1000 ...
Страница 185: ...August 2022 Service and Repair Manual 173 Electrical Schematic PCON from Z60H 3000 Z60M 1000 ...
Страница 188: ...Service and Repair Manual August 2022 176 Electrical Schematic TCON from Z60H 3000 Z60M 1000 ...
Страница 189: ...August 2022 Service and Repair Manual 177 Wiring Diagram CAN BUS from Z60H 3000 Z60M 1000 ...
Страница 191: ...August 2022 Service and Repair Manual 179 Hydraulic Schematic ...