Seventh Edition • First Printing
Operator's Manual
Inspections
Part No. 1297932GT
Z
®
-30/20N • Z
®
-30/20N RJ
33
77
Insert the actuator into the switch socket.
Result: The lights and horn will turn off.
78
Operate each machine function.
Result: All machine functions should operate.
1
actuator
2
contact alarm cable
3
flashing alarm
4
switch socket
Test Auxiliary Power
79
Pull out the red Emergency Stop button to the
on position.
80
Press down the foot switch.
81
Simultaneously hold the auxiliary power switch
on and activate each function control handle or
toggle switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom and steer functions should
operate. Drive functions should not operate
with auxiliary power.
3
1
2
3
4
Содержание Genie Z-30N