April 2021
Service and Repair Manual
Control System
Part No. 1288652GT
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
33
4 Unscrew the nut holding the buttons and key
switch and remove the key switch and
buttons.
Note the orientation of the key switch so it can be
reassembled in the same position.
5 Disconnect the wire harness connected to the
DISCON and cut the zip ties securing the
harness to the ground box lid. Do not remove
the wire harness from the ground box.
6 Remove the DISCON door (4) and disconnect
the ribbon cables (3) from the Display
Controller (DISCON) (2). Note the orientation
of the cables for reassembling.
1 ground box lid
2 DISCON
3 ribbon cables
4 DISCON door
5 Torx head screws
7 Remove the ground box lid (1) from the
ground box.
8 Remove the old overlay and clean the ground
box lid surface from any dirt, oils or old
adhesive residue. Clean the lid with 99%
isopropyl alcohol. Allow the surface to
completely dry.
9 Before placing the new overlay, make sure
the temperature of the lid and overlay is
between 80-100° F / 26-38° C. Application
below 80° F / 26° C is not recommended.
10 Peel the adhesive protective film from the
back of the overlay. Carefully align the
overlay, making sure the LCD screen cutout,
push buttons and key switch are centered.
Apply the overlay to the ground box, applying
pressure evenly to eliminate any air bubbles.
Note: Pay particular attention to the outside edges,
the LCD cutout edges and the area around the
ribbon cables, making sure there is complete
contact between the overlay and the ground box.
Note: It is not recommended peeling and
reapplying the overlay, so take time to align the
overlay before making contact with the ground
box.
11 Maintain the temperature of 80-100° F / 26-
38° C for a minimum of 20 minutes to allow
the adhesive to cure.
12 Install the provided ribbon cables, first to the
overlay and then the DISCON. Be sure the
connectors are applied evenly in the sockets
and the tabs are fully locked.
13 Reinstall the DISCON door using the Torx
head screws (5). Tighten, but do not
overtighten.
14 Reinstall the ground box door to the ground
box, using the fasteners removed in step 7.
Tighten the fasteners securely.
Содержание Genie S-60 HF
Страница 89: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 77 ...
Страница 91: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 79 ...
Страница 93: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 81 ...
Страница 95: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 83 ...
Страница 103: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 91 ...
Страница 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Страница 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Страница 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Страница 202: ...Service and Repair Manual April 2021 190 Electrical Schematic Deutz D2011 L03i TD2011 L04i Models ...
Страница 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Страница 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Страница 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Страница 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Страница 211: ...April 2021 Service and Repair Manual 199 Hydraulic Schematics Hydraulic Schematic from S65XCM 101 to S65XCM 302 ...
Страница 217: ......