April 2021
Service and Repair Manual
Perkins 404-22 Engine Fault Codes
Part No. 1288652GT
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
165
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
FMI
Description
3251
3
Particulate Trap Differential Pressure:
Voltage Above Normal
3251
4
Particulate Trap Differential Pressure:
Voltage Below Normal
3473
7
Aftertreatmert #1 Failed to Ignite: Not
Responding Properly
3473
11
Aftertreatmert #1 Failed to Ignite :
Other Failure Mode
3484
0
Aftertreatmert #1 Ignition : High-most
severe (3)
3484
3
Aftertreatmert #1 Ignition : Voltage
Above Normal
3484
4
Aftertreatmert #1 Ignition : Voltage
Below Normal
3556
6
Aftertreatmert 1 Hydrocarbon Doser
1: Current Above Normal
3610
3
Diesel Particulate Filter Outlet
Pressure or 1: Voltage Above
Normal"
3610
4
DieselParticulate Filter Outlet
Pressure Sensor 1: Voltage Below
Normal
3713
7
DPF Active Regeneration Inhibited
Due to System Timeout: Not
Responding Properly
3713
31
DPF Active Regeneration Inhibited
Due to System Timeout
3719
0
Particulate Trap #1 Soot Load
Percent: High- most severe (3)
3719
16
Particulate Trap #1 Soot Load
Percent: High-moderate severity (2)
4016
6
High Current Auxiliary Power Relay 1:
Current Above Normal
4201
3
Engine Speed Sensor #1: Voltage
Above Normal
SPN
FMI
Description
4201
4
Engine Speed Sensor #1: Voltage
Below Normal
4201
8
Engine Speed Sensor #1: Abnormal
Frequency, Pulse \Nidth, or Period
4201
10
Engine Speed Sensor #1: Abnormal
Rate of Change
4765
1
Aftertreatmert #1 Diesel Oxidation
Catalyst Intake Gas Temperature:
Low-most severe (3)
4765
3
Aftertreatmert #1 Diesel Oxidation
Catalyst Intake Gas Temperature:
Voltage Above Normal
4765
4
Aftertreatmert #1 Diesel Oxidation
Catalyst Intake Gas Temperature:
Voltage Below Normal
4765
15
Aftertreatmert #1Diesel Oxidation
Catalyst Intake Gas Temperature:
High-least severe (1)
4765
16
Aftertreatmert #1 Diesel Oxidation
Catalyst Intake Gas Temperature:
High-moderate severity (2)
5487
3
Aftertreatmert 1 Burner Unit
Combustion Chamber Temperature:
Voltage Above Normal
5487
4
Aftertreatmert 1 Burner Unit
Combustion Chamber Temperature:
Voltage Below Normal
6581
6
Aftertreatmert 1 Hydrocarbon Doser
2 : Current Above Normal
Содержание Genie S-60 HF
Страница 89: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 77 ...
Страница 91: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 79 ...
Страница 93: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 81 ...
Страница 95: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 83 ...
Страница 103: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 91 ...
Страница 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Страница 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Страница 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Страница 202: ...Service and Repair Manual April 2021 190 Electrical Schematic Deutz D2011 L03i TD2011 L04i Models ...
Страница 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Страница 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Страница 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Страница 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Страница 211: ...April 2021 Service and Repair Manual 199 Hydraulic Schematics Hydraulic Schematic from S65XCM 101 to S65XCM 302 ...
Страница 217: ......