Service and Repair Manual
April 2021
Control System Fault Codes
140
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
Part No. 1288652GT
ID Component ID Name
Cause
Effect
Solution
100 Platform
Level Up Coil
11 Shorted
to supply
voltage
PCON detected
that V14PLU circuit
is shorted to 12 V
or GND.
Platform Level Up
and possibly Level
Down functions will
not operate.
* With a voltmeter, measure Y20. Proper
resistance should be between 5 -
60 ohms. Replace Y20 if resistance is
outside of those values.
* Verify wiring for V14PLU (OR, PCON
J12-6) and check for open or short
circuits.
101 Platform
Level Down
Coil
11 Shorted
to supply
voltage
PCON detected
that V15PLD circuit
is shorted to 12 V
or GND.
Platform Level
Down and possibly
Level Up functions
will not operate.
* With a voltmeter, measure Y19. Proper
resistance should be between 5 -
60 ohms. Replace Y19 if resistance is
outside of those values.
* Verify wiring for V15PLD (OR/BK,
PCON J12-7) and check for open or
short circuits.
110 Platform
Rotate
Toggle
Switch @PC
27 Active at
startup
Toggle switch input
was detected as
HIGH at start-up.
Platform Rotate Left
or Right will not
operate, depending
on which side of the
switch was faulted.
*Verify with a voltmeter that the Platform
Rotate Toggle Switch (TS7) is operating
properly.
* C17PRL (GR, PCON J16-4) and
C18PRR (GR/BK, PCON J17-5) should
be 12 V when the switch is pressed in
their respective directions.
*Cycle power to allow the machine to re-
test the fault.
116 Model
Configuration
31 Setup
invalid.
Machine is not fully
configured or set to
wrong model.
Machine will not
operate.
Navigate to Settings -> Model
Configuration and ensure model,
engine, tires, and region are set and
correct.
141 Boom
10 Safety
Envelope
Exceeded
The system has
determined that
the platform
position has
exceeded the
safety envelope
boundary.
All functions will not
operate except for
the recovery
procedure.
Use Auxiliary Power and the boom
retract and/or down functions to
bring the platform back within the
operational envelope.
150 Sensor
Power
P26PWR
11 Shorted
to supply
voltage
PCON detected
that P26PWR
circuit is shorted to
12 V or GND.
Boom Up and
Extend functions
will not operate.
* Turn on machine and verify sensor
power P26PWR (BK, PCON J13-9)
is at 12 V.
* Inspect wiring for open or shorts
circuits.
152 Primary
Boom
Up/Down
Flow Coil
11 Shorted
to supply
voltage
TCON detected
that C3PBF circuit
is shorted to 12 V
or GND.
Boom Up and Down
functions will not
operate.
* With a voltmeter, measure Y12.
Proper resistance should be
between 5 - 60 ohms. Replace
Y12 if resistance is outside of those
values.
* Verify wiring for C3PBF (RD/WH,
TCON J4-4) and check for open or
short circuits.
* Verify resistance between
Recovery Module pins J37-3 and
J37-10 is zero ohms.
Содержание Genie S-60 HF
Страница 89: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 77 ...
Страница 91: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 79 ...
Страница 93: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 81 ...
Страница 95: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 83 ...
Страница 103: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 91 ...
Страница 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Страница 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Страница 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Страница 202: ...Service and Repair Manual April 2021 190 Electrical Schematic Deutz D2011 L03i TD2011 L04i Models ...
Страница 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Страница 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Страница 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Страница 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Страница 211: ...April 2021 Service and Repair Manual 199 Hydraulic Schematics Hydraulic Schematic from S65XCM 101 to S65XCM 302 ...
Страница 217: ......