120
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
Part No. 1288652GT
ID Component ID Name
Cause
Effect
Solution
80 Turntable
Controller
(TCON)
13 Not
detected
The DISCON has
not detected the
TCON on the
CAN bus.
Machine will
not be
functional.
* Verify TCON is receiving power. Check for
12 V on J5-2 (+) and J5-1 (-).
* Verify TCON is receiving ESTOP signals.
With ground ESTOP pulled out and keyswitch
set to Ground, verify 12 V is reaching TCON
J5-9 and J5-12.
* Verify CAN bus is functional. Pull out
connector J5 from the TCON and with a
voltmeter set to resistance verify that pins
3 and 4 on the harness connector measure
between 55 and 65 Ohms. Check wiring and
boom cable for open or short circuits if
resistance check fails.
* Replace TCON if necessary.
36 Incorrect
software
version
TCON's
secondary
processor
software revision
does not match
the system
revision level.
Reprogram the machine with latest software.
Check http://firmware.genielift.com/ for the
latest software version.
83 Telematics
21 Remote
disable
The telematics
module has
locked out
machine
operation.
Machine will
not be
functional, or
have limited
functionality,
depending
on the
telematics
option.
Call machine owner to re-enable machine
functions.
84 Turntable Tilt
Sensor
13 Not
detected
The tilt sensors
(S8O and/or
S8S) have not
been detected on
the CAN bus.
Boom Up,
Extend and
Drive
functions will
not operate.
* Verify S8O is receiving power. Disconnect
sensor connector and verify harness connector
pins 1 and 2 measure 12 V.
* Verify S8S is receiving power. Disconnect
sensor connector and verify harness connector
pins 1 and 2 measure 12 V.
* Verify CAN bus wiring. With a voltmeter set to
resistance, check the resistance between pins
3 and 4 on the harness connector (not the
sensor's integrated connector). Resistance
should be between 55 and 65 ohms. Check
CAN wiring if resistance check fails.
* Replace sensor if required.
17 Invalid
calibration
The tilt sensors
have no valid
calibration data,
either because
the sensor(s)
were replaced or
the prior
calibration was
cleared from
memory or was
unsuccessful.
Boom Up
and Extend
functions will
not operate.
Perform the tilt sensor calibration process.
Содержание Genie S-60 HF
Страница 89: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 77 ...
Страница 91: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 79 ...
Страница 93: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 81 ...
Страница 95: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 83 ...
Страница 103: ...April 2021 Service and Repair Manual Manifolds Part No 1288652GT S 60 65 XC S 60 65 HF S 60 65 TraX 91 ...
Страница 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Страница 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Страница 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Страница 202: ...Service and Repair Manual April 2021 190 Electrical Schematic Deutz D2011 L03i TD2011 L04i Models ...
Страница 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Страница 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Страница 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Страница 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Страница 211: ...April 2021 Service and Repair Manual 199 Hydraulic Schematics Hydraulic Schematic from S65XCM 101 to S65XCM 302 ...
Страница 217: ......