February 2022
Service Manual
Diagnostics
Part No. 1314708GT
GRC
™
91
Charger status indicators
Remote charger status indicators
1 Error / Fault / USB indicator
2 Charger profile / Error display
3 Error / Fault
Charg er Fault Cod es
Charger Fault Codes
Fault Code
Description
Possible Causes
Solution
F-0-0-1
DC-DC failure: LLC excessive leakage
fault.
Internal charger fault.
Disconnect AC input and battery
pack for 30 seconds.
If fault does not clear, contact
Genie Product Support.
F-0-0-2
PFC failure: PFC excessive leakage
fault.
F-0-0-3
PFC taken too long to boost.
F-0-0-4
Charger unable to calibrate current
offset.
F-0-0-5
Output relay voltage too high when
closed.
Содержание Genie GRC-12
Страница 110: ...Service Manual February 2022 Wiring Diagram Ground and Platform Controls 98 GRC Part No 1314708GT...
Страница 113: ...February 2022 Service Manual 101 Electrical Schematic GRC Options...
Страница 115: ...February 2022 Service Manual 103 Electrical Schematic GRC from GRC11 1000 to GRC11 1078...
Страница 118: ...Service Manual February 2022 106 Electrical Schematic GRC from GRC11 1000 to GRC11 1078...
Страница 119: ...February 2022 Service Manual 107 Electrical Schematic GRC from GRC11 1079 to GRC14 1780...
Страница 122: ...Service Manual February 2022 110 Electrical Schematic GRC from GRC11 1079 to GRC14 1780...
Страница 123: ...February 2022 Service Manual 111 Electrical Schematic GRC from GRC14 1781 to GRC15 2343...
Страница 126: ...Service Manual February 2022 114 Electrical Schematic GRC from GRC15 2344 to GRC16P 2481...
Страница 127: ...February 2022 Service Manual 115 Electrical Schematic GRC from GRC16P 2482 to GRC16P 2562...
Страница 130: ...Service Manual February 2022 118 Electrical Schematic GRC from GRC16P 2563 to GRCP 5999...
Страница 131: ...February 2022 Service Manual 119 Hydraulic Schematic GRC from GRC11 1000 to GRC12 1168...
Страница 135: ......