5 Installation of generator
340-1560-12.65-113
2
1
Magnet cable to the hydraulic cylinder unit (front view)
Lead the magnet cable (1) out of the open-
ing to the hydraulic cylinder unit (2).
After the magnet socket is connected,
close all hose brackets and fasten the
magnet cable with cable ties.
340-1560-12.65-114
5
2
4
1
3
6
Parts required for magnet socket
Preparations for the magnet socket
The illustration shows the parts for the mag-
net socket. The magnet plug is similar and
must be placed ready as well.
1) Magnet socket housing
2) Fastening screws for magnet socket on
dipperstick
3) Terminal screws for housing
4) Clamping screws and nuts for housing
5) Cable
clamp
6) Contacts (with fastening screws)
340-1560-12.65-115
1
2
3
Cable end clamping
Screw the cable ends (3) onto the contacts
(1) with fastening screws (2).
Make certain while doing this that the ca-
ble end is resting evenly on the contact
and that the fastening screw covers the
cable end on all sides.
12.65-SA10403-en-110808
Version 11.08.2008