TROUBLESHOOTING
SPRAY PUMP FAILED TO TURN ON
Step
Action
Value(s)
Yes
No
1
• Key ON
• Enable spray pump
• Is there a fl ashing BDI fault or LCD Pro-Panel (option)
fault code present?
See FAULTS
in TROUBLE-
SHOOTING sec-
tion of this manual
Proceed to
STEP 2
2
• Key OFF
• Firmly press circuit breaker #3 to reset
• Is circuit breaker #3 tripped?
Reset and test
power-up circuit
operation
Proceed to
STEP 3
3
• Key ON
• Enable spray pump
• Test voltage applied to spray pump subsystem as shown
on electrical schematic
• Are electrical circuits operating as shown on electrical
schematic?
Repeat STEP 1
Identify voltage
drop location
and repair or re-
place necessary
components
Terms:
BDI = Battery Discharge Indicator