48
T500 9015504 01-2018
TROUBLESHOOTING
BDI (Battery
Discharge
Indicator)
☼
= Flashing
Pro-Panel
LCD
Faults
(Option)
Fault Condition
Reason
Correction
☼
●
☼
☼
●
0x0507
Vacuum FET Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor, ac-
tuator, wand pump, detergent
pump, vacuum and battery
watering pump.
0x0607
Detergent Pump FET
Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor, ac-
tuator, wand pump, detergent
pump, vacuum and battery
watering pump.
0x0617
Wand Pump FET
Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor, ac-
tuator, wand pump, detergent
pump, vacuum and battery
watering pump.
0x0717
ec-H2O FET Faults
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor, ac-
tuator, wand pump, detergent
pump, vacuum and battery
watering pump.
0x0B17
Battery Watering
Pump FET Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor, ac-
tuator, wand pump, detergent
pump, vacuum and battery
watering pump.
☼
●
☼
☼
☼
0x0503
Vacuum Over Current
Fault
1. Current draw higher than expected.
Check harness and vacuum.
0x0504
Vacuum Over Current
1 Fault
1. Current draw higher than expected.
Verify vacuum load, damage
and/or usage conditions.
0x0505
Vacuum Over Current
2 Fault
1. Current draw higher than expected.
Verify vacuum load, damage
and/or usage conditions.
0x0506
Vacuum Shorted Load
Fault
1. Shorted load condition.
2. Some higher current draw than
hardware design limit.
Check harness and vacuum.
☼
☼
●
●
●
0x0613
Wand Pump Over
Current Fault
1. Current draw higher than expected.
2. Some higher current draw than
hardware design limit.
Verify fl oor, pad, and down
pressure combination are ap-
propriate for machine.
Check actuator.
0x0614
Wand Pump Over
Current 1 Fault
1. Current draw higher than expected.
Verify fl oor, pad, and down
pressure combination are ap-
propriate for machine.
Check actuator.
0x0615
Wand Pump Over
Current 2 Fault
1. Current draw higher than expected.
Verify fl oor, pad, and down
pressure combination are ap-
propriate for machine.
Check actuator.
0x0616
Wand Pump Short
Fault
1. Shorted load condition.
2. Some higher current draw than
hardware design limit.
Check wire harness and
repair as needed.
Содержание t500
Страница 5: ...5 T500 9015504 01 2018 CONTENTS ...
Страница 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Страница 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Страница 111: ...111 T500 9015504 01 2018 SERVICE ...
Страница 117: ...117 T500 9015504 01 2018 SERVICE ...
Страница 146: ...146 T500 9015504 01 2018 SERVICE ...