![Tennant t500 Скачать руководство пользователя страница 118](http://html1.mh-extra.com/html/tennant/t500/t500_service-information-manual_1087311118.webp)
118
T500 9015504 01-2018
SERVICE
REMOVING / INSTALLING THE WATER SOLENOID
VALVE
FRONT
Water
solenoid
valve
Button screws
(Qty. 2)
In-line filter
Rear frame
To: Scrub
head
To:
Solution tank
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, remove
key, and set parking brake if equipped.
FOR SAFETY: When servicing machine, Disconnect
battery connection and charger cord before
working on machine.
1. Completely drain both the recovery tank and the
solution tank.
2. Turn the key to the OFF position.
3. Disconnect the battery cable from the machine.
4. Remove the batteries from the machine and set the
batteries aside.
FOR SAFETY: When servicing machine, avoid
contact with battery acid, keep all metal objects off
batteries, and use a hoist or adequate assistance
when lifting batteries.
5. Remove the rear squeegee assembly from the
machine. Set the rear squeegee assembly aside
and hardware aside.