113
T500 9015504 01-2018
SERVICE
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, remove
key, and set parking brake if equipped.
1. Remove the orbital scrub head assembly from the
machine. See
REMOVE / INSTALL THE ORBITAL
SCRUB HEAD ASSEMBLY
in this section of the
SERVICE MANUAL.
2. Place the scrub head on a work bench.
3. Loosen the nyloc nuts securing the lower isolators
to the orbital scrub head assembly.
4. Turn the orbital scrub head assembly upside down
and remove the pads. Set the pads aside.
5. Remove hardware securing the lower plate to the
lower isolators.
6. Loosen the set screw securing the concentric
motor weight to the motor shaft.
7. Remove the lower plate and the lower isolators.
8. Install the lower orbital head isolators in the reverse
order in which they were removed.