OPERATION
59
8010 330100 (9--97)
Problem
Cause
Remedy
Excessive dusting.
Brush skirts and dust seals worn,
damaged, out of adjustment.
Replace or adjust brush skirts or
dust seals.
Hopper dust filter clogged.
Shake and/or clean or replace
dust filter.
Sweeping vacuum will not
activate.
Make sure hopper is in the
lowered position
Reset Thermo Sentry
t
Contact Tennant service
representative.
Thermo Sentry
t
tripped.
Reset Thermo Sentry
t
.
Poor sweeping performance.
Brush bristles worn.
Replace brushes.
Sweeping brushes not properly
adjusted.
Adjust brushes.
Debris caught in brush drive
mechanism.
Remove debris.
Brush drive failure.
Contact Tennant service
representative.
Hopper full.
Empty hopper.
Hopper lip skirts worn or
damaged.
Replace lip skirts.
Содержание 8010