Tenma 72-10390A Скачать руководство пользователя страница 8

www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk

TM

TM

Page <8>

V1.0

22/08/18

Important Notice : 

This data sheet and its contents (the “Information”) belong to the members of the Premier Farnell group of companies (the “Group”) or are licensed to it. No licence is granted 

for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change 

without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any 

error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any 

 

assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the 

Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence. 

Tenma is the registered trademark of the Group. © Premier Farnell Limited 2016.

Operating Steps:

1. Turn the power in “off” situation, then remove the test lead out of the meter.
2. Use screwdriver to take off the screw on the battery cover. Then you can take off old battery for replacing
3. User screwdriver to take off two pieces of screws, then you can replacing the burned fuse(s) as replacement.

Fuse Specification 

:  F1 Fuse Ø6.35 × 31.8mm, F 10A H 600V

 

F2 Fuse Ø6.35 × 31.8mm, F 0.5A H 600V

Содержание 72-10390A

Страница 1: ...www element14 com www farnell com www newark com www cpc co uk TM TM Page 1 V1 0 22 08 18 Palm Size Digital Multimeter 72 10390A User Manual ...

Страница 2: ...rating manual otherwise the protection provided by the meter may be impaired 1 Before using the meter inspect the case Do not use meter if it is damaged the case or part of the case is removed Look for cracks or missing plastic Pay attention to the insulation around the connections 2 Inspect the test leads for damaged insulation or exposed metal Replace damaged test leads with identical model numb...

Страница 3: ...easurement Operation First check on 9V battery then turn rotary switch to the measuring position If the low battery sign will be displayed on LCD panel Nearly to sign on the meter front panel terminal input which also not exceed the testing voltage and current input value limitation 1 DC or AC Voltage Measurement See Diagram 2 1 Turn rotary switch to V or V voltage measurement 2 Insert the red tes...

Страница 4: ...Ω ohm measurement 2 Insert the red test lead into the Ω terminal and the black test lead into the COM terminal Connect the test leads across with the object being measured The measured value shows on the display The LCD displays OL indicating open circuit for the tested resistor or the resistor value is higher than the maximum range of the meter To maintain the resistance measurement accuracy disc...

Страница 5: ...The open circuit of diodes is 2 3V Do not input higher than DC 60V and AC 30V voltage to prevent any damage and accident 5 Temperature Measurements see diagram 7 1 Turn rotary switch to C 2 K type point contact temperature probe can only be used in the measurement below 230 C you need to separately buy another temperature probe 3 The LCD displays OL indicating point contact temperature probe which...

Страница 6: ...Current Range Resolution Accuracy 2000µA 1µA 1 Reading 2 Digits 20mA 0 01mA 1 Reading 2 Digits 200mA 0 1mA 1 2 Reading 2 Digits 10A 0 01A 2 Reading 5 Digits Overload Protection mA Range F2 fuse Ø6 35 x 31 8mm F 0 5A H 600V CE 10A Range F1 fuse Ø6 35 x 31 8mm F 10A H 600V CE Warning When 5A Continuous measurement is allowed When 5A Continuous measurement less than 10 seconds at an interval more tha...

Страница 7: ...Ω Buzzer beep continuously Overload Protection 600V AC or DC 7 Maintenance and Service Warning Make sure the test leads take off the terminal and the circuit as well as power off the meter if want to open the meter cover 1 General Service and Maintenance Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Any abnormal on the meter stop use the meter and...

Страница 8: ...selves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted Liability for loss or damage resulting from any reliance on the Information or use of it including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising is excluded This will not operate to li...