www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
TM
TM
Page <6>
V1.0
22/08/18
Input Impedance
: All range 10MΩ
Maximum Input Voltage : 600V DC
2. AC Voltage
Range
Resolution
Accuracy
200V
0.1V
±(1.2% Reading % +3 Digits)
600V
1V
Input Impedance
: about 4.5MΩ
Frequency
: 45Hz ~ 400Hz
Display
: Effective value of sine wave (average value) each measurement is applicable from 5% of range as
reference.
Maximum Input Voltage : 600V AC
3. DC Current
Range
Resolution
Accuracy
2000µA
1µA
±(1% Reading + 2 Digits)
20mA
0.01mA
±(1% Reading + 2 Digits)
200mA
0.1mA
±(1.2% Reading + 2 Digits)
10A
0.01A
±(2% Reading + 5 Digits)
Overload Protection:
mA Range
: F2 fuse Ø6.35 x 31.8mm, F 0.5A H 600V (CE)
10A Range
: F1 fuse Ø6.35 x 31.8mm, F 10A H 600V (CE)
Warning:
•
When ≤5A Continuous measurement is allowed.
•
When >5A Continuous measurement less than 10 seconds at an interval more than 15 minutes
4. Resistance
Range
Resolution
Accuracy
200Ω
0.1Ω
±(0.8% Reading + 5 Digits)
2000Ω
1Ω
20kΩ
0.01kΩ
200kΩ
0.1kΩ
2000kΩ
1kΩ
20MΩ
0.01MΩ
±(1% Reading + 5 Digits)
200MΩ
100kΩ
±(5% Reading -10) + 10 Digits)
Overload Protection
: 600V AC or DC