11.  The internal circuit of the meter shall not be altered that will avoid damages of the meter and any accident Soft cloth and 

mild detergent should be used to clean the surface of the meter when servicing. No abrasive and solvent should be used to 

prevent the surface of the meter from corrosion, damage and accident.

12.  Please check whether the instrument is in good condition before use, such as test the voltage which is known and confirm 

the reading are accurate.

3. International Electrical Symbols

Deficiency of Built in Battery

Grounding

Warning: Refer to the Operating Manual
AC (Alternating Current)
DC (Direct Current)
Double Insulated
Conforms to Standards of European Union

4. The Meter Structure (see diagram 1)

1. LCD Display                   
2. Power Button
3. Rotary Switch

4. Input Terminals

5. Hold Button

5. Measurement Operation

First check on 9V battery, then turn rotary switch to the measuring position. If the low battery, “ ” sign will be displayed on LCD 

panel. Nearly to “ ” sign on the meter front panel terminal input which also not exceed the testing voltage and current input 

value limitation.

1. DC or AC Voltage Measurement (See Diagram 2)

1) Turn rotary switch to V~ or V

 voltage measurement.

2)  Insert the red test lead into the “V” terminal and the black test lead into the “COM” terminal, connect the test leads across with 

the object being measured. The measured value show on the display AC Voltage measurement shows on True root mean 

square value stability period.

3)  In each range, the meter has an input impedance of 10MΩ. V ~ Input impedance is about 4.5MΩ. This loading effect can 

cause measurement errors in high impedance circuits. In the circuit impedance is less than or equal to 10kΩ, the error is 

negligible (0.1% or less).

 Warning:

  

To avoid possibly damages to the meter, please do not attempt to input higher than 600V. 

To avoid electrical shock, please pay attention during the high voltage measurement.

Содержание 72-10390A

Страница 1: ...www element14 com www farnell com www newark com www cpc co uk TM TM Page 1 V1 0 22 08 18 Palm Size Digital Multimeter 72 10390A User Manual ...

Страница 2: ...rating manual otherwise the protection provided by the meter may be impaired 1 Before using the meter inspect the case Do not use meter if it is damaged the case or part of the case is removed Look for cracks or missing plastic Pay attention to the insulation around the connections 2 Inspect the test leads for damaged insulation or exposed metal Replace damaged test leads with identical model numb...

Страница 3: ...easurement Operation First check on 9V battery then turn rotary switch to the measuring position If the low battery sign will be displayed on LCD panel Nearly to sign on the meter front panel terminal input which also not exceed the testing voltage and current input value limitation 1 DC or AC Voltage Measurement See Diagram 2 1 Turn rotary switch to V or V voltage measurement 2 Insert the red tes...

Страница 4: ...Ω ohm measurement 2 Insert the red test lead into the Ω terminal and the black test lead into the COM terminal Connect the test leads across with the object being measured The measured value shows on the display The LCD displays OL indicating open circuit for the tested resistor or the resistor value is higher than the maximum range of the meter To maintain the resistance measurement accuracy disc...

Страница 5: ...The open circuit of diodes is 2 3V Do not input higher than DC 60V and AC 30V voltage to prevent any damage and accident 5 Temperature Measurements see diagram 7 1 Turn rotary switch to C 2 K type point contact temperature probe can only be used in the measurement below 230 C you need to separately buy another temperature probe 3 The LCD displays OL indicating point contact temperature probe which...

Страница 6: ...Current Range Resolution Accuracy 2000µA 1µA 1 Reading 2 Digits 20mA 0 01mA 1 Reading 2 Digits 200mA 0 1mA 1 2 Reading 2 Digits 10A 0 01A 2 Reading 5 Digits Overload Protection mA Range F2 fuse Ø6 35 x 31 8mm F 0 5A H 600V CE 10A Range F1 fuse Ø6 35 x 31 8mm F 10A H 600V CE Warning When 5A Continuous measurement is allowed When 5A Continuous measurement less than 10 seconds at an interval more tha...

Страница 7: ...Ω Buzzer beep continuously Overload Protection 600V AC or DC 7 Maintenance and Service Warning Make sure the test leads take off the terminal and the circuit as well as power off the meter if want to open the meter cover 1 General Service and Maintenance Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Any abnormal on the meter stop use the meter and...

Страница 8: ...selves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted Liability for loss or damage resulting from any reliance on the Information or use of it including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising is excluded This will not operate to li...

Отзывы: