Q: Can I use output ports when T320 is charging?

A: Yes you can.

Q: How long will this power station run my device?

A: Runtime hours depend on typical power consumption (how 
many watt) your application requires. Find the typical power 
consumption of your device from its manufacturer, and then divide 
300 by the typical wattage consumption. For example: Airsense 10 
CPAP has a typical power consumption of 53W. 300 / 53 = 5.6 
hours. A fully charged T320 can run Airsense 10 CPAP for about 
5.6 hours per charge.

Q: What kind of solar panel is compatible?

A: Any solar panel with 5V ~ 24V DC output will provide enough 
charging voltage to charge your T320 unit via solar. But for 
significant charging speed, we recommend solar panels of 60W. 
For example, the Tenergy 60W solar panel.

Q: Why is T320 keep turning itself off in a few 

minutes when powering my small applications?

A: Most likely caused by the wattage of your application is too low 
and triggered the auto turn off feature. To keep your low-wattage 
application running without interrupting. Please manually turn off 
the auto turn off feature (see page 7).

Q: Can I take the T320 on an airplane?

A: Please call the respective of airline to check before you took it to 

airport. Inform them it's a lithium-ion battery of 300 watt-hours, and ask 

for confirmation on compliance.

Q: “AC!” or "Temperature" icon shows up on the 

screen, and it’s not working.

A: This can mean one or more of the following issue:

Over load protection: remove the overloaded application that plugged 
onto T320, press the power button to reset the unit.

Short circuit: same as over loading, remove application and press the 
power button to reset.

Over heat protection: let the unit cool down a few minutes, then press 
the power button and see if gets back to normal condition. If not, give it 
another few minutes.

Q: I tried everything but it’s still not working or not 

meeting my needs.

A: Please contact our customer service team for further assistance. 

Q: Why can’t I use it power my coffee maker?

A: Typical coffee maker has power of 800+watts. Which is higher 

than the 200watt AC output limitation of T320. Same idea for other 

applications such as air dryer, heater, cooker, or anything excess 

200Watts.

Q: It will not stay on even it still has N% left.

A: Using the unit in high temperature locations may make the unit 

running hot, and has its over temperature protection triggered 

even when it still has power in it. Do not use this unit under direct 

sun when the weather is hot, keep it in the shade and keep it well 

ventilated will help with lowering the temperature.

Q: Is the battery replaceable?

A: The internal battery is not replaceable, but if it’s maintained 

well, it can be recharged for up to 2000 times. Which provides a 

very long life span.

Q: Can I keep the unit plugged to AC power?

A: It’s not recommended, as it will slightly reduce the life span of 

the unit over time, however, if you find it difficult to charge the unit 

when its power level is low. Or you plan to put it in storage for over 

a year without charging. Keeping it plugged into the AC power 

while storing is doable to prevent over discharge.

FAQS & TROUBLESHOOTING

9

Содержание 59148

Страница 1: ...POWER STATION USER GUIDE PN 59148...

Страница 2: ...CHARGE ME NOW Before using or storing plug your Tenergy T320 unit into the wall until it is fully charged...

Страница 3: ...le Do not disassemble the power pack take it to a qualified service person when service or repair is required Incorrect reassembly may result in a risk of fire or electric shock To reduce the risk of...

Страница 4: ...F CONTENTS WHAT S IN THE BOX GET TO KNOW YOUR UNIT HOW IT WORKS CHARGING YOUR UNIT USING YOUR UNIT STORAGE MAINTENANCE TECHNICAL SPECIFICATIONS FAQS TROUBLESHOOTING WARRANTY CONTACT US 1 1 2 3 4 8 8 9...

Страница 5: ...B ports 2 LED light 6 LCD screen 10 AC outlets 3 12V 10A DC output 7 DC power button 11 USB C port 4 12V 8A DC outputs 8 AC power button 1 2 3 4 5 6 7 8 9 10 11 WHAT S IN THE BOX GET TO KNOW YOUR UNIT...

Страница 6: ...ctual charging time varies depending on weather conditions and degree of excellence of sunlight reception Phone 30 Charges Mini Cooler 60W 22 Hours Laptop 4 5 Charges Lamp 9W 35 Hours Tablet 9 Charges...

Страница 7: ...power and becomes more efficient at converting energy into power to recharge the power station Charge through AC adapter Connect your T320 unit to the wall outlet with the AC adapter that comes with y...

Страница 8: ...ING Ensure that the total wattage of all AC devices simultaneously plugged into the AC outlets not exceed 200 watts If overloading occurs please remove the overloaded application and press the power b...

Страница 9: ...via any of the DC output ports USB USB C DC socket car port that fits your application connector Press the DC power button to enable DC power output you ll know it s enabled by seeing the DC power bu...

Страница 10: ...g activated Pressing the DC power when LED light is on will deactivate the LED light Abnormal Output Warning This icon indicates the power draw for the output ports is more than the power station can...

Страница 11: ...ion can be manually disabled To allow low applications that draw 3W or less to run follow these steps Press and hold BOTH DC power button and AC power button for 3 seconds 1 T320 will make 2 short bee...

Страница 12: ...t is always ready to use check the battery level frequently and fully recharge it every 3 to 6 months STORAGE MAINTENANCE TECHNICAL SPECIFICATIONS Model NO T320 Battery Cell Lithium ion LiFePO4 Capaci...

Страница 13: ...e manually turn off the auto turn off feature see page 7 Q Why can t I use it power my coffee maker A Typical coffee maker has power of 800 watts Which is higher than the 200watt AC output limitation...

Страница 14: ...tion that plugged onto T320 press the power button to reset the unit Short circuit same as over loading remove application and press the power button to reset Over heat protection let the unit cool do...

Страница 15: ...REMEDY TENERGY will repair or replace at TENERGY s option any TENERGY product that fails to operate during the applicable warranty period due to a defect in workmanship or material WARRANTY LIMITED TO...

Страница 16: ...12 CONTACT US THANK YOU 510 979 9969 Mon Fri 9am 5pm PST US LIVE CHAT service tenergy com power Tenergy com...

Страница 17: ...POWER STATION MODE D EMPLOI PN 59148...

Страница 18: ...CHARGEZ MOI MAINTENANT Avant d utiliser ou de stocker branchez votre appareil Tenergy T320 dans le mur jusqu ce qu il soit compl tement charg...

Страница 19: ...u un c ble de sortie endommag Ne d montez pas le bloc d alimentation apportez le un technicien qualifi lorsqu un entretien ou une r paration est n cessaire Un remontage incorrect peut entra ner un ris...

Страница 20: ...Y A T IL DANS LA BOITE APPRENEZ CONNA TRE VOTRE UNIT COMMENT A FONCTIONNE CHARGER VOTRE UNIT UTILISATION DE VOTRE UNIT ENTREPOSAGE ET MAINTENANCE SP CIFICATIONS TECHNIQUES FAQ D PANNAGE NOUS CONTACTE...

Страница 21: ...LED 6 cran LCD 10 Prises AC 3 Sortie 12V 10A DC 7 Bouton d alimentation DC 11 Port USB C 4 Sorties 12V 8A DC 8 Bouton d alimentation CA 1 2 3 4 5 6 7 8 9 10 11 QU Y A T IL DANS LA BOITE APPRENEZ CONNA...

Страница 22: ...rge r el varie en fonction des conditions m t orologiques et du degr d excellence de la r ception du soleil T l phone 30 charges Mini refroidisseur 60W 22 heures Portable 4 5 charges Lampe 9W 35 heure...

Страница 23: ...l nergie solaire et devient plus efficace pour convertir l nergie en nergie pour recharger la centrale Charge via l adaptateur secteur Connectez votre appareil T320 la prise murale avec l adaptateur...

Страница 24: ...sur le bouton d alimentation AC pour d sactiver la sortie AC AVERTISSEMENT Assurez vous que la puissance totale de tous les appareils AC branch s simultan ment sur les prises AC ne d passe pas 200 wa...

Страница 25: ...ie DC USB USB C prise DC port de voiture qui correspond votre connecteur d application Appuyez sur le bouton d alimentation DC pour activer la sortie d alimentation DC vous saurez qu il est activ en v...

Страница 26: ...iv e Appuyer sur l alimentation DC lorsque la lumi re LED est allum e d sactivera la lumi re LED Avertissement de sortie anormale Cette ic ne indique que la consommation lectrique des ports de sortie...

Страница 27: ...r autoriser les applications faibles qui consomment 3W ou moins s ex cuter proc dez comme suit Maintenez enfonc s les deux boutons d alimentation DC et AC pendant 3 secondes 1 Le T320 met 2 bips court...

Страница 28: ...appareil est toujours pr t l emploi v rifiez fr quemment le niveau de la batterie et rechargez la compl tement tous les 3 6 mois ENTREPOSAGE ET MAINTENANCE SP CIFICATIONS TECHNIQUES Mod le NO T320 Ce...

Страница 29: ...ctionne sans interruption Veuillez d sactiver manuellement la fonction d extinction automatique voir page 7 Q Pourquoi ne puis je pas l utiliser pour alimenter ma cafeti re R La cafeti re typique a un...

Страница 30: ...320 appuyez sur le bouton d alimentation pour r initialiser l unit Court circuit identique la surcharge supprimez l application et appuyez sur le bouton d alimentation pour r initialiser Protection co...

Страница 31: ...11 NOUS CONTACTER JE VOUS REMERCIE 510 979 9969 Mon Fri 9am 5pm PST US CHAT EN DIRECT service tenergy com power Tenergy com...

Страница 32: ......

Отзывы: