Start/Halt/Pause/Resume Frequency Scan ( F3)
Frequency Step (F5)
`
Add Lockout Frequency (F6)
Delete Lockout Frequency (F7)
Sets the step size of frequency scan (1 Hz steps) in P-SCAN mode
Format:
(Set command)
*
F5FFFFFFFFFF<cr>
(Get command)
?F5<cr>
Response:
F5FFFFFFFFFF<cr>
Definitions:
FFFFFFFFFF-Selects the step size in hertz entered in ASCII/decimal format. Leading zero’s
can be omitted. Range 1 Hz-3 GHz
Format:
(Set command)
*
F3X<cr>
(Get command)
?F3<cr>
Response: F3X<cr>
Definitions:
X
= <S> start programming frequencies for the specified range using command F2. If no range has been
specified using command F2, the receiver, the valid range will be from 0-3Ghz in 1hz increments if no step
size is specified via command F5. If command F5 has been received, the receiver will use the step size
specified in that command.
<H> halts or stops frequency scanning and returns to manual mode. The receiver will remain
tuned to frequency it is currently set to when receiving this command.
<P> Scanning will pause scanning if currently in scan mode. This command is ignored if not
currently in scan mode.
<R> resumes frequency scanning if currently in “paused” mode. Ignores this command if not
currently in paused mode
Frequency Step (F5)
7-13