Set Attack Rate (G1)
Set Hang Time (G3)
Unit Fault/Error Status (I1)
Set Decay Rate (G2)
Firmware Version (I2)
Set Hang Time (G3)
7-15
Format:
(Set command)
*G1NNNN<cr>
(Get command)
?G1<cr>
Response: G1NNNN<cr>
Definitions:
NNNN=Valid range 0001-9999 in ASCII decimal format. Leading zeros can be omitted.
The attack rate is used in automatic gain control (AGC) to select the rate to raise the volume for weak signals to try to maintain
an approximately constant average output level of varying signal levels.
Format:
(Set command)
*G2NNNN<cr>
(Get command)
?G2<cr>
Response:
G2NNNN<cr>
NNNN=Valid range 0001-9999 in ASCII decimal format. Leading zeros can be omitted.
The attack rate is used in automatic gain control (AGC) to select the rate to lower the volume for strong signals to try to
maintain an approximately constant average output level of varying signal levels.
Format:
(Set command)
*G3NNNN<cr>
(Get command)
?G3<cr>
Response: G3NNNN<cr>
NNNN=Valid range 0001-9999 in ASCII decimal format. Leading zeros can be omitted.