Enable Ethernet Communications Port (E6)
Tune Frequency ( F1)
Tune Frequency (F1)
.
The F1 command allows the tuned frequency of the RX-400A to be set to any value between
100kHz and 3 Gigahertz in 1-Hz increments.
Format
:
(Set command)
*
F1FFFFFFFFFF<cr>
(Get command)
?F1<cr>
Response:
F1FFFFFFFFFF<cr>
Definitions:
FFFFFFFFFF-Selects the frequency to tune in hertz entered as10 ASCII/decimal format. Leading zeros can
be omitted. Range 2 MHz to 3 GHz
Example:
To tune a frequency of 235.67 MHz the value 235670000 will be entered.
To tune a value of 2 MHz 2000000 can be entered.
This command is used to select the start and end frequency range for P-SCAN mode which
allows the radio to search for activity in a given frequency range.
Format:
(Set command)
*
F2SSSSSSSSSS<dot>EEEEEEEEEE<cr>
(Get command)
?F2<cr>
Response: F2SSSSSSSSSS<dot>EEEEEEEEEE<cr>
Definitions:
SSSSSSSSSS --Selects the starting frequency in hertz. The value entered in 10 ASCII
/decimal format. Leading zeros can be omitted but the <dot> character must be transmitted to
differentiate between the start and end frequency values. Range 100kHz-3 GHz
EEEEEEEEEE-- Selects the ending frequency in hertz. The value entered in 10 ASCII
/decimal format. Leading zeros can be omitted. Range 100kHz-3 GHz
Format: (
Set command)
*E6<cr>
(Get command)
(Not applicable)
Definitions:
This command will enable Ethernet communications.
Start/End Frequency (F2)
7-12