20
www.templari.com
Frost proof
depth
min 250mm
Frost
proof
depth
•
Preparation of the base for condensate drain
•
Example 1 condensate drain (it is advisable inter the
condensate drain pipe to avoid ice if you don’t buy the
optional
heating element for the condensate drain).
•
Prepare the laying of electrical cables.
•
In places where there are snowfalls, install the heat pump
at least 25 cm from the ground to avoid clogging at the
inlet and drain zone.
6.5 Assembly of the heat pump
1. Before installing the product, observe the safety warnings
content in this manual and service manuals.
2. Assembly the product on steel beams, blocks of concrete
or with the help of a wall holder (accessory).
3. Verify that under the product water doesn’t accumulate
non si accumuli.
4. Verify that the floor in front of the product can well absorb
water to avoid ice formation.
6.6 Preparation of the condensate drain
The condensate is discharged in a centralized way from the back
of the heat pump
KITA Templari®.
Prepare the condensate drain through a drain pipe or a gravel
bed.
WARNINGS!
The condensate frozen on the avenues can cause falls. Verify that
the condensate doesn’t flow on the avenues and can’t freeze on
them.
Frost proof
depth
min 250mm
Frost
proof
depth
Frost proof
depth
min 250mm
Frost
proof
depth
Frost proof
depth