![Teltone TSP Base Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/teltone/tsp-base/tsp-base_user-manual_1084662047.webp)
Figure 30 T1/E1 Wink Start Call Status
On T1/E1 Wink Start operation, there will be no
(ringing) or Ringing Status due to the nature of
the protocol operation. An
(off-hook) or
(on-hook) from the equipment under test will be the
only indication on the TSP screen. See Figure 30.
End-to-End Control Set Example
The Control Set for End-to-End operation is configured as discussed in the Control Sets section
except there are two template fields for End-to-End operation. For this example we will use
Switch Emulation with POTS and T1 Channels.
1.
Go to
Control Sets
menu and choose
New
. Name the Control Set “
End-to-End example
” and
click
OK
.
2.
On the Control Set screen, select
Switch Emulation
for the
Control Set Type
.
3.
Create a new template by clicking
New
next to the
Template
field just below the Control Set
Type field. Name the Template “
Analog LS
”. Choose
Analog Loop Start
for the Channel
Protocol and click
OK
.
4.
Click
New
at the second Template field. Name the Template “
T1 Wink St
”. Choose
T1/E1
Wink Start
for the Channel Protocol and click
OK
.
The names “Analog LS” and “T1 Wink St” will appear in the Template fields on the Control
Set screen.
Programming the TSP
40-400-00049, Rev. J
Page 41