The green status LED on the front panel will indicate the status of the system. The LED should be
solid green. If the LED fails to light, disconnect power immediately and contact Teltone Technical
Support at 425-951-3390.
Important
Adequate airflow must be maintained in order for the unit to operate correctly. Do not wrap the
unit in blankets, paper or other material that may impede ventilation.
Software Installation Instructions
The TSP software is supplied on a CD-ROM disk and uses the common Windows setup routine.
Ensure you have the latest version (Version 2.5 at the time this was written) by going to the
Teltone web site, and verifying the version available under Software Downloads for the TSP or
call Technical Support 425-951-3390.
An autorun facility will initiate the installation process automatically when the CD-ROM is installed
into the disk drive. An alternative method to perform the installation is to insert the CD-ROM, then
select START, RUN, BROWSE, then choose your CD-ROM drive, and the file labeled
SETUP.EXE. Follow the on screen instructions.
Important
It will be necessary to obtain an Authorization Code from Teltone Customer Service after the first
Unit is created with the configuration software to enable testing with the TSP. Once the
Authorization Code is installed, the TSP can be used with any PC using the current configuration
software version. See Authorization Code in the Units section for complete instructions.
For information about the current and previous versions of the software, see page 78.
Operational Strategy
The TSP uses a GUI based configuration software program that allows a user to define the TSP
using
Units
,
Templates
,
Control Sets
, and
Options
. These parameters are saved as a
Project
found on the
File
menu.
The
Unit
definition defines the communications interface, the installed hardware and some
generic definitions of each module. The
Templates
define the channel operating characteristics
and timings. The
Control Set
definition defines the group(s) of individual channels and their
interactions. Once these items have been defined, a
Control Set
button will appear. When a
Control Set Enables
button is selected, this begins the running of the particular application.
Quick Start
Configuration of the TSP via the Windows GUI is very flexible and allows the user to configure the
TSP in a straightforward manner. This section is to assist in configuring the TSP in minimal time
but is not intended to take the place of the rest of the manual. The basic process for setting up
the unit is described in the following subsections.
Hardware and Software Setup
1.
Install the modules as required per the Module Interface Matrix section.
2.
Connect the Serial and Ethernet cables according to the Basic Hardware Setup section.
Note
The Ethernet connection is not necessary unless you are prompted that newer code is available
or you are using audio files. See Step 5 in “Units Configuration” if needed.
3.
Ensure the modules are firmly seated and connect the power cord to the unit per the Power
up the TSP section. Turn on the TSP.
4.
Follow the Software Installation Instructions section of the manual.
Configuring the TSP/Hardware and Software
40-400-00049, Rev. J
Page 9