40-400-00022 Rev. B
21
New Value : _
Select entry > 27
OUTGOING CALL PRIORITY
0 = Disable
1 = Enable
Current Value: 0 (Disable)
New Value : _
The Teltone DS-100 allows the configuration of each port, including the
Modem port and Local Maintenance port. This configuration includes baud
rate, data bits, parity, stop bits, flow control (hardware vs software), service
request (for outgoing calls), cascading operation (for expansion up to 64
ports). The Modem port does not have the service request or cascading
function, but does have an initialization string. The Local Maintenance port
has an AutoBAUD function that supports operation from 300 to 9600 BAUD.
Enabling the CASCADING function will change the transfer code to a 4 digit
entry for a User port. For example, to transfer through User port 1 (unit 1) on
the DS-100 and connect to User port 4 (unit 2), the transfer code is ab14.
With this method, a single 8 port DS-100 connected to 8 more DS-100 units
will yield a 64 port configuration, yet use only 1 transfer code to access each
User port.
DEFAULT PORT configuration allows for incoming calls to be sent directly to
a Default Port without having to enter a transfer code. Other ports remain
accessible by entering the proper transfer code.
RECONNECT TO LAST ACCESSED PORT configuration allows a experi-
enced user to call in and select a port for an intermittent customer and have
the next call connected to the last accessed port if the call is placed within
the DATA INACTIVITY TIME-OUT (menu item 25, default 3 minutes).
PORT ROLLOVER TIME-OUT configuration allows for the DS-100 to roll
over to the next port whenever there is no data sent for the duration of the
PORT ROLLOVER TIME-OUT. The feature is disabled by default and allows
for access to other User Ports without having to enter a new transfer code.
Each time the rollover occurs, the port name will be sent to the caller.
2.
PORT CONFIGURATION
Select entry > 40
MODEM PORT CONFIGURATION
Baud:
19200
Data Bits:
8
Parity:
NONE
Stop bits:
1
Flow Control:
HARDWARE (RTS/CTS)
Initialization:
ATZ^MATS0=1
CHANGE? (Y/N)_
BAUD RATE
0 = 300
4 = 4800
1 = 600
5 = 9600
2 = 1200
6 = 19200
3 = 2400
7 = 38400