![Teltone DS-104 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/teltone/ds-104/ds-104_product-manual_1084656025.webp)
40-400-00022 Rev. B
23
Cascading:
Disabled
CHANGE? (Y/N)_
Select entry > 42
PORT 2 CONFIGURATION
Name:
USER 2
Baud:
19200
Data Bits:
8
Parity:
NONE
Stop Bits:
1
Flow Control:
HARDWARE (RTS/CTS)
Service Request:
NONE
Cascading:
Disabled
CHANGE? (Y/N)
y
PORT NAME
10 characters maximum
Current Value: USER 2
New Value (enter name, or <SPACE> to clear):
BAUD RATE
0 = 300
4 = 4800
1 = 600
5 = 9600
2 = 1200
6 = 19200
3 = 2400
7 = 38400
Current Value: 6 (19200)
New Value :
DATA BITS (5-8)
Current Value: 8
New Value :
PARITY
0 = NONE
3 = MARK
1 = EVEN
4 = SPACE
2 = ODD
Current Value: 0 (NONE)
New Value :
STOP BITS
0 = 1 bit
1 = 1.5 bits
2 = 2 bits
Current Value: 0 (1 bit)
New Value :
FLOW CONTROL
0 = NONE
1 = HARDWARE (RTS/CTS)
2 = SOFTWARE (XON/XOFF)
Current Value: 1 (HARDWARE RTS/CTS)
New Value :