background image

TSUR-400

 

 
The TSUR-400 is a continuous frequency band PSK uplink receiver/monitor which can receive, 
decode, analyze, display, and store digital messages from the Argos Platform Terminal Transmitters 
(PTTs).  The software within the TSUR-400 accommodates the latest Argos data formats and the full 
frequency band of PTTs. 
 

Scope 

 
This manual is designed to assist in configuring the TSUR-400 and to guide the user through the 
programming features.  The TSUR-400 displays various screens, which enable the user to easily learn 
and operate the unit. 
 

General Functional Guidelines 

 
Before commencing operation, make sure the battery is charged and properly attached.  Using the 
battery charger provided, the battery can be charged individually by inserting the spacer, or it can be 
charged while attached to the TSUR-400.  Make sure the antenna is properly attached. 
 
Four keys labeled FN (P0), DN (P1), UP (P2), and PWR (P3) are used to control and set all functions.  
Each key is variable dependant upon the current screen displayed on the TSUR-400.  Please refer to 
Appendix C, TSUR-400 Menu Flow Chart at the back of this manual. 
 

FN (P0) Key 

The FN key operates as a Function Key and is used to access the various menus, advance or accept 
setup parameters, and toggle menu items On or Off.  The FN key is also used to exit from the Message 
screen or to enter the Menu system.      
 

DN (P1) Key 

The DN key is a scroll down key used for scroll down menu options.  The DN key also decreases a 
value or field when in a Level 1 or 2 menu option.  Pressing the DN key when in the Main screen will 
take the user to the Message screen.   

 

UP (P2) Key 

Depressing the UP key will scroll upwards in a menu, or increase a value or field when in a Level 1 or 
2 menu option.  When in the Main screen, pressing the UP key will display the Splash screen for 3 
seconds.  Pressing the Up key in the Message screen will display the Main screen. 
 

PWR (P3) Key  

The PWR key turns the unit’s power or display backlight ON or OFF.  Depressing the key for 3 
seconds when the TSUR-400 is Off will turn the unit ON.  Depressing and holding the key again for 3 
seconds minimum will turn the TSUR-400 OFF.  When the unit is ON, sitting at the main message 
screen waiting for a message, briefly depressing the key will enable the display’s backlight for the 
configured time period.  Momentarily depressing the PWR key again before the backlight time-out will 
deactivate the backlight.  Depressing any other key when the backlight is ON will restart the backlight 
time-out period.  When the user is in either Menu Level 1 or Menu Level 2 screens the P3 key may be 
used as a quick escape key to return to the main screen. 
 

   

PB007326 Rev E
Page 3 of 24

 

 

Содержание TSUR-400

Страница 1: ...E MAIL info telonics com www telonics com TSUR 400 RECEIVER MONITOR OPERATION and PROGRAMMING MANUAL PB007326 Rev E 2012 08 07 Copyright Notice Copyright 2012 Telonics Inc All Rights Reserved No part...

Страница 2: ...xport 9 J Msg Delete 10 K Setup 10 Setup Menu Level 2 Screen 11 A 28bit Id Tbl 11 B Edit Id Fltr 12 C Split Setup 13 D Beep Tone 13 E Lite On Time 13 F Set Time 14 G Set Date 14 H Sw Closure 14 I Sque...

Страница 3: ...d toggle menu items On or Off The FN key is also used to exit from the Message screen or to enter the Menu system DN P1 Key The DN key is a scroll down key used for scroll down menu options The DN key...

Страница 4: ...een which displays the current date and time number of stored messages selected group or all ID codes data bytes split or decimal and diagnostics dg on or off Changes or modifications to these paramet...

Страница 5: ...automatically whenever a new message is received or manually by pressing the DN key at the Main screen The information displayed is the date and time of the most recent message current message number...

Страница 6: ...t a time with the most recent message displayed first The scroll speed increases when the UP or Dn key is depressed for more than 2 seconds When the last message is scrolled a message indicating end o...

Страница 7: ...haracter on white background with a black block Pressing the FN key allows the selected function to be modified Exiting back to the Main Screen is accomplished by selecting EXIT using the UP or DN key...

Страница 8: ...RF Pwr mode before directly connecting it to a transmitter You may damage the TSUR 400 if you directly connect a transmitter while it is in receive mode 4 Comparison of the number of data groups the...

Страница 9: ...is Off All is displayed on the left side of the bottom line of the display When Id Fltr is On the receiver will display information only when a new message is received for an ID that is in the GRouP o...

Страница 10: ...sed to begin the process Press the FN key to return to the Main Screen When exporting messages the following parameters define how the information is sent RS 232 9600 Baud 8 Bits No Parity 1 Stop Bit...

Страница 11: ...enu screen Line 1 Exit Line 2 28bit Id Tbl Line 3 Edit Id Fltr Line 4 Split setup Beep Tone Lite On Time Set Time Set Date SW Closure Squelch Fact Default RF Pwr Dsply PC connect A 28bit Id Tbl The 28...

Страница 12: ...coming messages or just selected messages maximum of 9 Edit Id Fltr is selected by highlighting the feature and pressing the FN key The following display appears Choices are Exit Erase All or Edit or...

Страница 13: ...rated when a beep occurs When this feature is selected and the FN key pressed the following appears Choices are 1 to 9 with each number corresponding to a different tone Each time a new number is sele...

Страница 14: ...ction mm Selection between 01 and 12 is accomplished using the UP DN keys When the correct number is displayed the FN key advances the highlight to the day selection dd Selection between 01 and 31 is...

Страница 15: ...t J Fact Default Warning Implementing this function will erase ID codes the user may have programmed into the TSUR 400 This feature is used to return the unit to the factory defaults that were origina...

Страница 16: ...e reading programming of user parameters and reading clearing of stored messages Note When the receiver is in this mode the RF section is disabled precluding reception of messages When this feature is...

Страница 17: ...fff fff ddd ddd eee CR where LF ASCII Line Feed code 0x0A y year decimal 2001 2002 etc M month decimal 1 12 d day of month decimal 1 31 h hour decimal 0 23 m minute decimal 0 59 s second decimal 0 59...

Страница 18: ...0 FF eeee error messages Alpha letters CR ASCII Carriage Return code 0x0D d Diagnostics Mode with Split Bits COMMA delimited field information as follows LF yyyy MM dd hh mm ss iiiiii fff fff CCC pp p...

Страница 19: ...l message received was longer or shorter than the message length indicated by the three bit message length indicator which was transmitted b Length Parity Error Indicates that the three bit message le...

Страница 20: ...External Power 9 to 48 Vdc with power adapter pack Power Measurement 0 01 to 1 watt 0 to 30 dBm For measuring power levels exceeding 1 0 watt 30 dBm appropriate external attenuators are required NOTE...

Страница 21: ...ORANGE and will remain ORANGE for two to three minutes until the charger brings the battery to the correct voltage level It will then turn RED to indicate that the charger is in the rapid charge state...

Страница 22: ...gin Msg Delete None UP DN Select FN Accepts Exit 28Bit ID Tbl Edit ID Filt Split setup Beep Tone Lite On Time Set Time Set Date Sw Closure Squelch Fact Default RF Pwr Dsply PC Connect Bit Splt 001 00...

Страница 23: ...orks with Telonics Data Converter and terminal programs Using Telonics Data Converter TDC TDC is available for download on the Telonics website and will save TSUR 400 messages to a text file free of c...

Страница 24: ...n STOP and data collection to the text file will be terminated TSUR 400 WARRANTY Telonics warrants the TSUR 400 to be free from defects in material and workmanship for 90 days from the date acquired T...

Отзывы: