right COM port can be difficult if you are using a virtual com port (TSC-5A or USB-to-serial adapter).  
Select 

OK. 

 
Step 3

.  COM X Properties 

Dialogue Box 

Port Settings Tab

   Five option fields exist They should be 

filled in as follows: 9600, 8, None, 1, Hardware. 
 
Step 4.  If HyperTerminal is configured properly, the data transfer cable connected and the uplink is 
turned on and receiving Argos uplink messages, data will appear in the HyperTerminal window as 
collected. If data do not appear after transmissions are received by the uplink, recheck the selection of 
the COM port.  Selection of the wrong COM port is a common problem. To change the COM port, 
select the icon for DISCONNECT.  Go to PROPERTIES and change the COM port setting to the 
correct COM port. Use the CALL icon to reconnect and check for received data from the uplink on the 
next transmission.  
 
Step 5.  When you are certain the configuration is correct and you see the data transfer to the 
HyperTerminal window is occurring, go to the task bar and select FILE, then SAVE or SAVE AS to 
save the proper configuration of HyperTerminal for future use with the TSUR-400.  Select 

SAVE.

 

This selection does not save the received uplink data but saves the configuration of HyperTerminal for 
future use. 
 
Step 6.  To start the creation of a text file to save Argos uplink data, go to 

TRANSFER

 then 

CAPTURE TEXT

.  A dialogue box will ask you for the directory and file name where the data will be 

saved. After supplying the file name, data are collected from that point forward. To stop data 
collection, go to TRANSFER then CAPTURE TEXT then STOP and data collection to the text file 
will be terminated.  
 
 
 
 
 
 

TSUR-400 WARRANTY:  Telonics warrants the TSUR-400 to be free from defects in material and workmanship for 90 
days from the date acquired. Telonics does not warrant batteries.   

If a defect occurs, return the equipment to us within the proper time frame at the following address: TELONICS, 932 E. 
IMPALA AVENUE, MESA, AZ USA 85204-6699. Damage to any equipment resulting from misuse, accidents, 
unauthorized service, extreme conditions, or other causes, is excluded from this warranty. Telonics does not assume 
responsibility for loss or damage to equipment during shipment. Telonics does not assume responsibility for delays 
resulting from shipment on commercial or private carriers. We insure all equipment shipped from our facility and suggest 
that shipments to Telonics also be insured.   

Upon the timely return to our facility, if defective, the product will be replaced or repaired at our discretion at no cost to the 
customer. This remedy is the exclusive remedy. This product is supplied without any further warranties or conditions, 
expressed or implied, including warranties of merchantability, quality or fitness for particular reason or those arising by 
laws, statutes or trade usage or course of dealing. 

The entire risk, as to the results and performance of the product, is assumed by the customer. Neither Telonics, nor its 
suppliers, shall have any liability to the customer or any other person or entity for any indirect, incidental, special, or 
consequential damage whatsoever, regardless whether Telonics has been told of the possibility of such damages or that 
such damages might be foreseeable. Telonics has no responsibility or liability for the claims of any third party. The 
maximum aggregate to the customer, of Telonics and its suppliers, shall not exceed the amount paid by the customer for the 
product. 

Содержание TSUR-400

Страница 1: ...E MAIL info telonics com www telonics com TSUR 400 RECEIVER MONITOR OPERATION and PROGRAMMING MANUAL PB007326 Rev E 2012 08 07 Copyright Notice Copyright 2012 Telonics Inc All Rights Reserved No part...

Страница 2: ...xport 9 J Msg Delete 10 K Setup 10 Setup Menu Level 2 Screen 11 A 28bit Id Tbl 11 B Edit Id Fltr 12 C Split Setup 13 D Beep Tone 13 E Lite On Time 13 F Set Time 14 G Set Date 14 H Sw Closure 14 I Sque...

Страница 3: ...d toggle menu items On or Off The FN key is also used to exit from the Message screen or to enter the Menu system DN P1 Key The DN key is a scroll down key used for scroll down menu options The DN key...

Страница 4: ...een which displays the current date and time number of stored messages selected group or all ID codes data bytes split or decimal and diagnostics dg on or off Changes or modifications to these paramet...

Страница 5: ...automatically whenever a new message is received or manually by pressing the DN key at the Main screen The information displayed is the date and time of the most recent message current message number...

Страница 6: ...t a time with the most recent message displayed first The scroll speed increases when the UP or Dn key is depressed for more than 2 seconds When the last message is scrolled a message indicating end o...

Страница 7: ...haracter on white background with a black block Pressing the FN key allows the selected function to be modified Exiting back to the Main Screen is accomplished by selecting EXIT using the UP or DN key...

Страница 8: ...RF Pwr mode before directly connecting it to a transmitter You may damage the TSUR 400 if you directly connect a transmitter while it is in receive mode 4 Comparison of the number of data groups the...

Страница 9: ...is Off All is displayed on the left side of the bottom line of the display When Id Fltr is On the receiver will display information only when a new message is received for an ID that is in the GRouP o...

Страница 10: ...sed to begin the process Press the FN key to return to the Main Screen When exporting messages the following parameters define how the information is sent RS 232 9600 Baud 8 Bits No Parity 1 Stop Bit...

Страница 11: ...enu screen Line 1 Exit Line 2 28bit Id Tbl Line 3 Edit Id Fltr Line 4 Split setup Beep Tone Lite On Time Set Time Set Date SW Closure Squelch Fact Default RF Pwr Dsply PC connect A 28bit Id Tbl The 28...

Страница 12: ...coming messages or just selected messages maximum of 9 Edit Id Fltr is selected by highlighting the feature and pressing the FN key The following display appears Choices are Exit Erase All or Edit or...

Страница 13: ...rated when a beep occurs When this feature is selected and the FN key pressed the following appears Choices are 1 to 9 with each number corresponding to a different tone Each time a new number is sele...

Страница 14: ...ction mm Selection between 01 and 12 is accomplished using the UP DN keys When the correct number is displayed the FN key advances the highlight to the day selection dd Selection between 01 and 31 is...

Страница 15: ...t J Fact Default Warning Implementing this function will erase ID codes the user may have programmed into the TSUR 400 This feature is used to return the unit to the factory defaults that were origina...

Страница 16: ...e reading programming of user parameters and reading clearing of stored messages Note When the receiver is in this mode the RF section is disabled precluding reception of messages When this feature is...

Страница 17: ...fff fff ddd ddd eee CR where LF ASCII Line Feed code 0x0A y year decimal 2001 2002 etc M month decimal 1 12 d day of month decimal 1 31 h hour decimal 0 23 m minute decimal 0 59 s second decimal 0 59...

Страница 18: ...0 FF eeee error messages Alpha letters CR ASCII Carriage Return code 0x0D d Diagnostics Mode with Split Bits COMMA delimited field information as follows LF yyyy MM dd hh mm ss iiiiii fff fff CCC pp p...

Страница 19: ...l message received was longer or shorter than the message length indicated by the three bit message length indicator which was transmitted b Length Parity Error Indicates that the three bit message le...

Страница 20: ...External Power 9 to 48 Vdc with power adapter pack Power Measurement 0 01 to 1 watt 0 to 30 dBm For measuring power levels exceeding 1 0 watt 30 dBm appropriate external attenuators are required NOTE...

Страница 21: ...ORANGE and will remain ORANGE for two to three minutes until the charger brings the battery to the correct voltage level It will then turn RED to indicate that the charger is in the rapid charge state...

Страница 22: ...gin Msg Delete None UP DN Select FN Accepts Exit 28Bit ID Tbl Edit ID Filt Split setup Beep Tone Lite On Time Set Time Set Date Sw Closure Squelch Fact Default RF Pwr Dsply PC Connect Bit Splt 001 00...

Страница 23: ...orks with Telonics Data Converter and terminal programs Using Telonics Data Converter TDC TDC is available for download on the Telonics website and will save TSUR 400 messages to a text file free of c...

Страница 24: ...n STOP and data collection to the text file will be terminated TSUR 400 WARRANTY Telonics warrants the TSUR 400 to be free from defects in material and workmanship for 90 days from the date acquired T...

Отзывы: