Climatic and mechanical
tests
Test severities according to EN 300 019-2:
• Storage:
Test specification T 1.2
• Transportation:
Test specification T 2.3
• In use:
Test specification T 3.2 and T 3.3
Test sequence for
storage and
transportation
The table specifies the test sequence for storage and transportation.
Shock
Shock spectrum type I
11 ms 100 m/s
2
Shock spectrum type L
22 ms 40 m/s
2
Fall
1.2 m
-
Parameter
Storage and Transportation
In use
Parameter
Severity
Reference
Temperature shocks
-40/30
°
C, 1
°
C/min.,
t=3h, 5 cycles
IEC 60068-2-14 Nb
Rapid temperature cy-
cle
-5/60
°
C, 5
°
C/min.,
t=3h, 2 cycles
DOT QM-333
Mechanical shocks
400m/s
2
, 6ms, 6 x 500
shocks
IEC 60068-2-29 Eb
Humidity, condensa-
tion
25/40
°
C, 90-100% RH,
2 days
IEC 60068-2-30 Db 1
Low Temperature
-40
°
C, 3 days
IEC 60068-2-1 Ab
High Temperature
85
°
C, 3 days
IEC 60068-2-2 Bb
Vibration, sinusoidal
5 - 9 - 200 - 500 Hz
3.5 mm - 10 - 15 m/s
2
1 octave/minute
3 x 5 sweep cycles
IEC 60068-2-6 Fc
High humidity
40
°
C, 93%RH, 4 days
IEC 60068-2-56 Cb
Free Fall
1 m
IEC 60068-2-32 Ed 1