MA365 • Rev. A2
71
Tellabs
®
6325 Edge Node
3 Reference Information
EMC immunity tests
The immunity and resistibility performance criteria are according to EN 300
386 subclass 12.3.
EMC immunity tests for
enclosure ports
Specifications for enclosure ports.
EMC immunity tests for
AC power supply ports
Specifications for AC power supply ports.
Conducted RF voltage
0.15 - 30 MHz
Quasi peak det.
Average det.
0.15 - 0.5 - 5.0 - 30 MHz
66 - 56 - 56/60 - 60 dB
µ
V
56 - 46 - 46/50 - 50 dB
µ
V
EN 55022
Class B
DC Power Supply Ports:
Conducted RF voltage
0.02 - 30 MHz
Quasi peak det.
Average det.
0.15 - 0.5 - 5.0 - 30 MHz
66 - 56 - 56/60 - 60 dB
µ
V
56 - 46 - 46/50 - 50 dB
µ
V
EN 55022
Class B and
EN 300 386
Phenomenon
Limits
Reference
Phenomenon
Test Level
Performance
Reference
Electrostatic Discharge
contact/air exposure
6kV/0-8kV
B
EN 61000-4-2
8kV/0-15kV
C
Electromagnetic Field
(26) 80 - 1000 MHz
80% AM, 1kHz
10 V/m
A
EN 61000-4-3
EN 300 386, sub
clause 12.2.2
Electromagnetic Field
GSM 900 MHz @ 200Hz
50% duty c.
10 V/m
A
ENV 50140
Phenomenon Test
Level
Performance
Reference
Voltage Dips and
Short Interruptions
> 95 %, 10 ms
B
EN61000-4-11
30 %, 500 ms
C
> 95 %, 5000 ms
C
Radio Frequency
CM Voltage
0.15 – 80 MHz
80 % AM, 1 kHz
10 V
A
EN 61000-4-6
EN 300 386,
sub clause
12.2.2
Fast Transients
rise time 5ns
decay time 50ns
1 kV
B
EN 61000-4-4
2 kV
C