The connectors on IP Bridge panel
LINE
Simulated telephone line for connecting alarm panel
Z1
1. contact input (considered between Z1 and COM)
COM
Common terminal between Z1 and Z2 contact inputs
Z2
2. contact input (considered between Z2 and COM)
Z3
3. contact input (considered between Z3 and COM)
COM
Common terminal between Z3 and Z4 contact inputs
Z4
4. contact input (considered between Z4 and COM)
Z5
5. contact input (considered between Z5 and COM)
COM
Common terminal between Z5 and Z6 contact inputs
Z6
6. contact input (considered between Z6 and COM)
TX
RS232 serial port TX
RX
RS232 serial port RX
GND
RS232 serial port GND
V+
Supply voltage 9-30V DC
V-
Supply voltage negative polarity (GND)
Outputs
OUT1
1. relay contact output, normally open (N. O.)
OUT2
2. relay contact output, normally open (N. O.)
OUT3
3. relay contact output, normally open (N. O.)
OUT4
4. relay contact output, normally open (N. O.)
OUT5
5. relay contact output, normally open (N. O.)
OUT6
6. relay contact output, normally open (N. O.)
4
Setup the alarm control panel
Check the followings on the alarm control panel you connected the IP Bridge module to:
•
Contact-ID communication format has to be set in the alarm control panel.
•
The alarm control panel must be configured for communication to monitoring station as it were using a
wired phone line.
•
Set the dialing to TONE mode.
•
Regardless the dialed phone number the IP Bridge emits the handshake signal and receives the Contact
ID events.