T. E. L. L. SOFTWARE
HUNGÁRIA KFT
42
Output:
The target module’s output
. In case it has a unique name, it is also displayed in the dropdown, else it
is listed by its sequence number.
Delay (sec):
The delay of activating the output can be defined in seconds.
Output mode (Figure 47.):
State change
: the event will cause a relay status change.
ON - Timed:
the event activates the relay output for the time set in Time
field in seconds. When the time is up the output becomes inactive again.
ON - Permanent:
the event activates the relay output permanently (the
relay output remains active until switching off or receiving status change
command).
OFF:
the event deactivates the relay output.
Time:
If the selected output mode is ON-Timed you need to add how long
the relay needs to stay switched ON.
Delete control module:
To delete a contol module use the dust-bin icon at the end of the row.
Control modules by external event:
Adding and configuring is the same as described above, but here only the external events added on Events
page can be selected to control an output.
Stop
: You can add multiple overlapping external events in the Events menu to control an output. If you select
the „Stop” option for an event, the external events th
at is specified below will not be evaluated.
Figure 47. Output mode