Playing a reminder 

The  recorded  reminders  can  be  replayed  by  pressing  shortly  the  corresponding  1-4 
function  keys,  provided  that  there  has  been  assigned  a  reminder  to  the  given  key 
previously. 

 

Erasing a reminder 

Steps of reminder erasing: 

1)  Press the Settings 

 

key continuously for at least 5 seconds, then “

PASS

” 

is displayed on the digital display 

2)  Enter the user password using the 1-4 function keys (the password is: 1111) 
3) 

The “MEM” LED becomes lit 

4)  The LED found above each 1-4 function key is lit if there is already a reminder 

assigned to the given key 

5)  Keep  pressed  for  at  least  5  seconds  the  function  key  (1-4)  assigned  to  the 

reminder to be erased. 

The LED found above the key turns off and “- - - -”  is 

displayed on the digital display 

6)  If you wish to erase further reminders, repeat the previous step (5) 

7)  When finished, press Cancel 

 key to exit the programming mode 

8)  If you have not deleted all the reminders, the "MEM" LED remains lit green 

 

Confirming a reminder 

The user can confirm the reminder by pressing the Cancel 

 key while the reminder 

is  being  played.  If  no  confirmation  is  done,  the  message  will  be  repeated  in  the 
configured  intervals  (5  to  30  seconds).  If  the  reminder  is  still  not  confirmed  after being 
repeated  according  to  the  configured  number  of  repetition  (1  to  10),  the  module 
generates  “

Reminder  unacknowledged

”  event  which  initiates  SMS  sending  or  call 

according  to  the  settings.  The  delay  between  reminder  repetitions  and  the  number  of 
repetitions can be configured using the programming software. 

2.4.4  Starting an emergency call 

Emergency calls can be initiated by pressing the Emergency 

 key or by pressing the 

button  on  the  RF  transmitter.  In  case  of  initiating  an  emergency  alarm  using  the  RF 
transmitter,  the  transmit

ter’s  LED  indicator  starts  flashing  with  red  light,  thereby 

indicating that  signal transmission is in  progress. The transmitter’s LED indicator turns 
green for 1-2 seconds if the signal transmission towards the device was successful, i.e. 
the  device  confir

med  the  reception.  In  case  that  the  transmitter’s  LED  indicator  keeps 

flashing  with  red  light,  it  means  that  for  some  reason  the  signal  does  not  reach  the 
device,  or  the  device’s  confirmation  does  not  reach  the  RF  transmitter  (i.e.  the  RF 
transmitter  is  ou

tside  the  operating  range).  At  a  single  press  of  the  RF  transmitter’s 

button the RF transmitter tries to send the signal towards the device  once per second, 
altogether  100  times,  i.e.  through  100  seconds.  The  operating  range  of  the  RF 
transmitter  depends  on  the  local  reception  conditions

,  therefore  it  is  the  installer’s 

responsibility to test the proper operation on the scene, as well as to mount the unit in 
the most optimal place, where it will be 

able to receive the RF transmitter’s signals from 

the desired distances, taking into account that the operating range of the RF transmitter 
decreases when its battery weakens. 

Содержание gsm easyaid

Страница 1: ...GSM easyAID Emergency call system INSTALLATION AND APPLICATION MANUAL for module version v2 07 0098 and higher Document version 1 52 30 08 2016...

Страница 2: ...estriction 12 3 Configuring the easyAID unit using the programming software 13 3 1 Configuration through USB connection 13 3 2 Configuration through modem connection 14 3 3 Configuring the parameters...

Страница 3: ...onversation with the user thus can help in discovering the point of the emergency call or perhaps the type of sick and allows reassuring the user remotely The device has high sensitivity microphone gr...

Страница 4: ...etime of its battery Attention The battery of the RF transmitter has to be replaced forthwith if RF transmitter battery low event is received as well as at least yearly independently of the reception...

Страница 5: ...se of transportation or storage follow the steps below Disconnect the power adapter from the module If you have connected the device to USB disconnect it Press the Settings key continuously for at lea...

Страница 6: ...In this case the display can be turned on for 30 seconds by pressing Cancel key 2 4 Configurable options in the easyAID unit The following options can be configured in the easyAID module Clock settin...

Страница 7: ...ly for 3 seconds to save 8 To add new phone number return to step 5 9 When finished press Cancel key to exit the programming mode The TEL LED is lit green continuously to indicate that there are phone...

Страница 8: ...he message after the beep as close as possible to the front of the device After the next beep the module replays the recorded message automatically 7 Keep the Settings key pressed for 3 seconds The ti...

Страница 9: ...ich initiates SMS sending or call according to the settings The delay between reminder repetitions and the number of repetitions can be configured using the programming software 2 4 4 Starting an emer...

Страница 10: ...ecause in case that the given phone number is not available this causes significant delay to the calls and SMS messages to be initiated to the next phone numbers The outgoing calls which are received...

Страница 11: ...assword is 1111 The digital display shows ok then 3 Keep the Cancel key pressed and press once function key 1 or 2 according to the number of the memory slot you wish to assign the given RF transmitte...

Страница 12: ...device therefore it may not be the subject of a quality complaint To reduce possible echo phenomenon there is possibility to adjust the speaker volume of the device during a conversation through DTMF...

Страница 13: ...which can be purchased separately 3 1 Configuration through USB connection Start the easyAID_GSM_Remoter program Choose the USB option in the Connection menu Power up the easyAID module Connect the m...

Страница 14: ...he USB RS232 adapter cable equipped with FTDI chip The programming software detects the connected device automatically Enter the phone number of the easyAID module to be connected in the Phone number...

Страница 15: ...requency it can be configured in hours between 1 and 168 how often the module should send a periodic test report message expediently in SMS This report serves for checking if the device operates o Tes...

Страница 16: ...se code a code consisting of digits 1 2 3 and 4 can be specified which can be used by the social workers nurses to confirm a visit The preset code can be entered on device using the 1 4 function keys...

Страница 17: ...cess of that event will be terminated when the 15 minutes period expires and that specific event will not be reported anymore Specification of the columns of the Custom events menu No the event s ordi...

Страница 18: ...occurs when the module s supply voltage drops below the 9V level for at least 3 minutes o Supply voltage restore this event occurs when the supply voltage rises above 10V for at least 10 seconds afte...

Страница 19: ...le Firmware update process Power up the easyAID module Establish the connection between the programming software and the easyAID module Select the corresponding firmware file after pressing Browse but...

Страница 20: ...s password is different from the password used to enter the user settings The module s password protects the software settings against unauthorized access The user password does not change by changin...

Страница 21: ...the Status menu easyAID Module section Firmware version version of the module s firmware and its issue date Internal clock the time setting of the connected module Temperature the measured actual envi...

Страница 22: ...y pressing this button when connected to the module State messages section This section shows the module s recent messages with date and time of generation It is possible to select which messages to b...

Страница 23: ...d 3 8 Software update The Update menu makes possible to select the programming software s update mode Update if Automatic update option is selected the program searches for new version on the internet...

Страница 24: ...inder message after the beep when recording a reminder First reminder when pressing function key 1 if the first reminder s time is set but no message is recorded Second reminder when pressing function...

Страница 25: ...e being programmed In normal operation mode is lit green if there are reminders set TEL LED When in programming mode is lit green if the phone number settings are selected Still in programming is lit...

Страница 26: ...the SIM card into the opened part with the contacts facing down as shown in the figure above Close back the opened part together with the SIM card Press down carefully and pull forward towards the di...

Страница 27: ...ming software In case of low signal achieve better signal by relocating the GSM antenna 6 Technical information 6 1 Technical specification Supply voltage 9 30VDC Nominal current consumption 180mA 12V...

Отзывы: