tell gsm easyaid Скачать руководство пользователя страница 12

 

12 

2.4.9  Voice call settings 

Incoming  calls  are  accepted  only  from  the  preconfigured  (up  to  4)  phone  numbers. 
Calls initiated from other phone numbers are rejected automatically. 
In  case  of  an  incoming  call  the  module  answers  the  call  automatically  in  hands-free 
mode after the configured number of rings. The call can be terminated by  pressing the 

Cancel 

  key,  or  by  the  caller.  The  call  is  also  terminated  if  an  emergency  call  is 

initiated. 
Due to the compact design of the device, its speaker and microphone are close to each 
other.  Therefore,  due  to  the  application  of  hands-free  mode,  it  may  happen  that  the 
caller  hears  his  own  voice  back  through  the  phone  during  a  conversation.  This  echo 
phenomenon is normal while using the device, therefore it may not be the subject of a 
quality complaint. 
To reduce possible echo phenomenon, there is possibility to adjust the speaker volume 
of  the  device  during  a  conversation  through  DTMF  commands  using  the  keys  of  the 
phone.  By  pressing  intermittently  key  3  on  the  phone  the  speaker  volume  can  be 
decreased, while pressing key 6 it can be increased.

   

2.4.10 SMS forwarding 

The SMS messages received on the SIM card of the device are forwarded automatically 
to  the  phone  number  set  in  memory  section  1.  (This  can  be  used  e.g.  for  forwarding 
pre-pay  card  balance  information  messages  received  from  the  GSM  service  provider). 
If no phone number is set in memory section 1, the device does not forward and deletes 
incoming SMS messages. 

2.4.11 SMS restriction 

The  device  has  built-in  SMS  restriction  function,  which  allows  sending  of  max.  50 
messages per 12 hours (regarding to the sum of the forwarded and alarm messages). 

Содержание gsm easyaid

Страница 1: ...GSM easyAID Emergency call system INSTALLATION AND APPLICATION MANUAL for module version v2 07 0098 and higher Document version 1 52 30 08 2016...

Страница 2: ...estriction 12 3 Configuring the easyAID unit using the programming software 13 3 1 Configuration through USB connection 13 3 2 Configuration through modem connection 14 3 3 Configuring the parameters...

Страница 3: ...onversation with the user thus can help in discovering the point of the emergency call or perhaps the type of sick and allows reassuring the user remotely The device has high sensitivity microphone gr...

Страница 4: ...etime of its battery Attention The battery of the RF transmitter has to be replaced forthwith if RF transmitter battery low event is received as well as at least yearly independently of the reception...

Страница 5: ...se of transportation or storage follow the steps below Disconnect the power adapter from the module If you have connected the device to USB disconnect it Press the Settings key continuously for at lea...

Страница 6: ...In this case the display can be turned on for 30 seconds by pressing Cancel key 2 4 Configurable options in the easyAID unit The following options can be configured in the easyAID module Clock settin...

Страница 7: ...ly for 3 seconds to save 8 To add new phone number return to step 5 9 When finished press Cancel key to exit the programming mode The TEL LED is lit green continuously to indicate that there are phone...

Страница 8: ...he message after the beep as close as possible to the front of the device After the next beep the module replays the recorded message automatically 7 Keep the Settings key pressed for 3 seconds The ti...

Страница 9: ...ich initiates SMS sending or call according to the settings The delay between reminder repetitions and the number of repetitions can be configured using the programming software 2 4 4 Starting an emer...

Страница 10: ...ecause in case that the given phone number is not available this causes significant delay to the calls and SMS messages to be initiated to the next phone numbers The outgoing calls which are received...

Страница 11: ...assword is 1111 The digital display shows ok then 3 Keep the Cancel key pressed and press once function key 1 or 2 according to the number of the memory slot you wish to assign the given RF transmitte...

Страница 12: ...device therefore it may not be the subject of a quality complaint To reduce possible echo phenomenon there is possibility to adjust the speaker volume of the device during a conversation through DTMF...

Страница 13: ...which can be purchased separately 3 1 Configuration through USB connection Start the easyAID_GSM_Remoter program Choose the USB option in the Connection menu Power up the easyAID module Connect the m...

Страница 14: ...he USB RS232 adapter cable equipped with FTDI chip The programming software detects the connected device automatically Enter the phone number of the easyAID module to be connected in the Phone number...

Страница 15: ...requency it can be configured in hours between 1 and 168 how often the module should send a periodic test report message expediently in SMS This report serves for checking if the device operates o Tes...

Страница 16: ...se code a code consisting of digits 1 2 3 and 4 can be specified which can be used by the social workers nurses to confirm a visit The preset code can be entered on device using the 1 4 function keys...

Страница 17: ...cess of that event will be terminated when the 15 minutes period expires and that specific event will not be reported anymore Specification of the columns of the Custom events menu No the event s ordi...

Страница 18: ...occurs when the module s supply voltage drops below the 9V level for at least 3 minutes o Supply voltage restore this event occurs when the supply voltage rises above 10V for at least 10 seconds afte...

Страница 19: ...le Firmware update process Power up the easyAID module Establish the connection between the programming software and the easyAID module Select the corresponding firmware file after pressing Browse but...

Страница 20: ...s password is different from the password used to enter the user settings The module s password protects the software settings against unauthorized access The user password does not change by changin...

Страница 21: ...the Status menu easyAID Module section Firmware version version of the module s firmware and its issue date Internal clock the time setting of the connected module Temperature the measured actual envi...

Страница 22: ...y pressing this button when connected to the module State messages section This section shows the module s recent messages with date and time of generation It is possible to select which messages to b...

Страница 23: ...d 3 8 Software update The Update menu makes possible to select the programming software s update mode Update if Automatic update option is selected the program searches for new version on the internet...

Страница 24: ...inder message after the beep when recording a reminder First reminder when pressing function key 1 if the first reminder s time is set but no message is recorded Second reminder when pressing function...

Страница 25: ...e being programmed In normal operation mode is lit green if there are reminders set TEL LED When in programming mode is lit green if the phone number settings are selected Still in programming is lit...

Страница 26: ...the SIM card into the opened part with the contacts facing down as shown in the figure above Close back the opened part together with the SIM card Press down carefully and pull forward towards the di...

Страница 27: ...ming software In case of low signal achieve better signal by relocating the GSM antenna 6 Technical information 6 1 Technical specification Supply voltage 9 30VDC Nominal current consumption 180mA 12V...

Отзывы: