tell gsm easyaid Скачать руководство пользователя страница 7

 

2.4.2  Setting the phone numbers 

1)  Press the Settings 

 key continuously for at least 5 seconds, then 

PASS

” 

is displayed on the digital display 

2)  Enter the user password using the 1-4 function keys (the password is: 1111) 

3)  Press the Settings 

 

key intermittently in the settings mode, until the ”TEL” 

LED becomes lit green 

4)  The  LED found  above  the function  key  (1-4)  is  lit  if  there  is  already  a  phone 

number stored in the given memory section 

5)  Keep  pressed  for  3  seconds  the  function  key  (1-4)  to  which  memory  section 

you  wish  to  add  (or  modify)  a  phone  number,  then  “-“  is  displayed  on  the 
digital  display  if  this  section  is  empty,  or  the  phone  number  stored  here 
previously.  The  LED  above  the  given  (1-4)  key  flashes  green  to  indicate  to 
which section the setting is in progress, while the “TEL” LED is lit red 

6)  Enter the phone number digit by digit using the 

 keys. You can shift 

to the next digit by pressing the Settings 

 key 

7)  After  entering  the  phone  number,  keep  the  Settings 

  key  pressed 

continuously for 3 seconds to save 

8)  To add new phone number, return to step 5 

9)  When  finished,  press  Cancel 

  key  to  exit  the  programming  mode. 

The  ”TEL”  LED  is  lit  green  continuously  to  indicate  that  there  are  phone 
numbers set. 

 

Erasing phone numbers: 

1)  Press the Settings 

 

key continuously for at least 5 seconds, then “

PASS

” 

is displayed on the digital display 

2)  Enter the user password using the 1-4 function keys (the password is: 1111) 

3)  Press the Settings 

 

key intermittently in the settings mode, until the ”TEL” 

LED becomes lit green 

4)  The  LED found above  the function  key  (1-4)  is  lit  if  there  is  already  a  phone 

number stored in the given memory section 

5)  Keep pressed for at least 5 seconds the function key (1-4) from which memory 

section  you  wish  to  erase  a  phone  number. The  LED found  above  the  given 
key turns off and the display indicates ”- - - -”  
(To  view  the  whole  phone  number,  you  can  scroll  the  digits  of  the  selected 
phone number using the 

 keys) 

6)  To erase further phone numbers, return to the previous step 

7)  When  finished,  press  Cancel 

  key  to  exit  the  programming  mode.  If  you 

have  not  erased  all  the  phone  numbers,  the  ”TEL”  LED  remains  lit  green 
continuously to indicate that there are phone numbers set. 

 

Содержание gsm easyaid

Страница 1: ...GSM easyAID Emergency call system INSTALLATION AND APPLICATION MANUAL for module version v2 07 0098 and higher Document version 1 52 30 08 2016...

Страница 2: ...estriction 12 3 Configuring the easyAID unit using the programming software 13 3 1 Configuration through USB connection 13 3 2 Configuration through modem connection 14 3 3 Configuring the parameters...

Страница 3: ...onversation with the user thus can help in discovering the point of the emergency call or perhaps the type of sick and allows reassuring the user remotely The device has high sensitivity microphone gr...

Страница 4: ...etime of its battery Attention The battery of the RF transmitter has to be replaced forthwith if RF transmitter battery low event is received as well as at least yearly independently of the reception...

Страница 5: ...se of transportation or storage follow the steps below Disconnect the power adapter from the module If you have connected the device to USB disconnect it Press the Settings key continuously for at lea...

Страница 6: ...In this case the display can be turned on for 30 seconds by pressing Cancel key 2 4 Configurable options in the easyAID unit The following options can be configured in the easyAID module Clock settin...

Страница 7: ...ly for 3 seconds to save 8 To add new phone number return to step 5 9 When finished press Cancel key to exit the programming mode The TEL LED is lit green continuously to indicate that there are phone...

Страница 8: ...he message after the beep as close as possible to the front of the device After the next beep the module replays the recorded message automatically 7 Keep the Settings key pressed for 3 seconds The ti...

Страница 9: ...ich initiates SMS sending or call according to the settings The delay between reminder repetitions and the number of repetitions can be configured using the programming software 2 4 4 Starting an emer...

Страница 10: ...ecause in case that the given phone number is not available this causes significant delay to the calls and SMS messages to be initiated to the next phone numbers The outgoing calls which are received...

Страница 11: ...assword is 1111 The digital display shows ok then 3 Keep the Cancel key pressed and press once function key 1 or 2 according to the number of the memory slot you wish to assign the given RF transmitte...

Страница 12: ...device therefore it may not be the subject of a quality complaint To reduce possible echo phenomenon there is possibility to adjust the speaker volume of the device during a conversation through DTMF...

Страница 13: ...which can be purchased separately 3 1 Configuration through USB connection Start the easyAID_GSM_Remoter program Choose the USB option in the Connection menu Power up the easyAID module Connect the m...

Страница 14: ...he USB RS232 adapter cable equipped with FTDI chip The programming software detects the connected device automatically Enter the phone number of the easyAID module to be connected in the Phone number...

Страница 15: ...requency it can be configured in hours between 1 and 168 how often the module should send a periodic test report message expediently in SMS This report serves for checking if the device operates o Tes...

Страница 16: ...se code a code consisting of digits 1 2 3 and 4 can be specified which can be used by the social workers nurses to confirm a visit The preset code can be entered on device using the 1 4 function keys...

Страница 17: ...cess of that event will be terminated when the 15 minutes period expires and that specific event will not be reported anymore Specification of the columns of the Custom events menu No the event s ordi...

Страница 18: ...occurs when the module s supply voltage drops below the 9V level for at least 3 minutes o Supply voltage restore this event occurs when the supply voltage rises above 10V for at least 10 seconds afte...

Страница 19: ...le Firmware update process Power up the easyAID module Establish the connection between the programming software and the easyAID module Select the corresponding firmware file after pressing Browse but...

Страница 20: ...s password is different from the password used to enter the user settings The module s password protects the software settings against unauthorized access The user password does not change by changin...

Страница 21: ...the Status menu easyAID Module section Firmware version version of the module s firmware and its issue date Internal clock the time setting of the connected module Temperature the measured actual envi...

Страница 22: ...y pressing this button when connected to the module State messages section This section shows the module s recent messages with date and time of generation It is possible to select which messages to b...

Страница 23: ...d 3 8 Software update The Update menu makes possible to select the programming software s update mode Update if Automatic update option is selected the program searches for new version on the internet...

Страница 24: ...inder message after the beep when recording a reminder First reminder when pressing function key 1 if the first reminder s time is set but no message is recorded Second reminder when pressing function...

Страница 25: ...e being programmed In normal operation mode is lit green if there are reminders set TEL LED When in programming mode is lit green if the phone number settings are selected Still in programming is lit...

Страница 26: ...the SIM card into the opened part with the contacts facing down as shown in the figure above Close back the opened part together with the SIM card Press down carefully and pull forward towards the di...

Страница 27: ...ming software In case of low signal achieve better signal by relocating the GSM antenna 6 Technical information 6 1 Technical specification Supply voltage 9 30VDC Nominal current consumption 180mA 12V...

Отзывы: